Suppr超能文献

膀胱癌放疗过程中膀胱体积和位置的分次间变化的锥形束 CT 成像分析。

Cone beam CT imaging analysis of interfractional variations in bladder volume and position during radiotherapy for bladder cancer.

机构信息

Department of Radiation Oncology, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada.

出版信息

Int J Radiat Oncol Biol Phys. 2010 Mar 15;76(4):1045-53. doi: 10.1016/j.ijrobp.2009.03.022. Epub 2009 Jun 18.

Abstract

PURPOSE

To quantify daily bladder size and position variations during bladder cancer radiotherapy.

METHODS AND MATERIALS

Ten bladder cancer patients underwent daily cone beam CT (CBCT) imaging of the bladder during radiotherapy. Bladder and planning target volumes (bladder/PTV) from CBCT and planning CT scans were compared with respect to bladder center-of-mass shifts in the x (lateral), y (anterior-posterior), and z (superior-inferior) coordinates, bladder/PTV size, bladder/PTV margin positions, overlapping areas, and mutually exclusive regions.

RESULTS

A total of 262 CBCT images were obtained from 10 bladder cancer patients. Bladder center of mass shifted most in the y coordinate (mean, -0.32 cm). The anterior bladder wall shifted the most (mean, -0.58 cm). Mean ratios of CBCT-derived bladder and PTV volumes to planning CT-derived counterparts were 0.83 and 0.88. The mean CBCT-derived bladder volume (+/- standard deviation [SD]) outside the planning CT counterpart was 29.24 cm(3) (SD, 29.71 cm(3)). The mean planning CT-derived bladder volume outside the CBCT counterpart was 47.74 cm(3) (SD, 21.64 cm(3)). The mean CBCT PTV outside the planning CT-derived PTV was 47.35 cm(3) (SD, 36.51 cm(3)). The mean planning CT-derived PTV outside the CBCT-derived PTV was 93.16 cm(3) (SD, 50.21). The mean CBCT-derived bladder volume outside the planning PTV was 2.41 cm(3) (SD, 3.97 cm(3)). CBCT bladder/ PTV volumes significantly differed from planning CT counterparts (p = 0.047).

CONCLUSIONS

Significant variations in bladder and PTV volume and position occurred in patients in this trial.

摘要

目的

定量膀胱癌放疗过程中膀胱的日常大小和位置变化。

方法与材料

10 例膀胱癌患者在放疗过程中接受每日锥形束 CT(CBCT)成像。比较了 CBCT 和计划 CT 扫描的膀胱和计划靶区(膀胱/PTV)在 x(侧)、y(前-后)和 z(上-下)坐标上的膀胱质心位移、膀胱/PTV 大小、膀胱/PTV 边界位置、重叠区域和互斥区域。

结果

从 10 例膀胱癌患者中总共获得了 262 个 CBCT 图像。膀胱质心在 y 坐标上移动最多(平均为-0.32cm)。前膀胱壁移动最多(平均为-0.58cm)。CBCT 衍生的膀胱和 PTV 体积与计划 CT 衍生体积的平均比值分别为 0.83 和 0.88。计划 CT 衍生膀胱体积外的 CBCT 衍生膀胱体积平均值(+/-标准差[SD])为 29.24cm3(SD,29.71cm3)。计划 CT 衍生膀胱体积外的 CBCT 衍生膀胱体积平均值为 47.74cm3(SD,21.64cm3)。计划 CT 衍生 PTV 外的 CBCT 衍生 PTV 平均值为 47.35cm3(SD,36.51cm3)。计划 CT 衍生 PTV 外的 CBCT 衍生 PTV 平均值为 93.16cm3(SD,50.21cm3)。计划 CT 衍生 PTV 外的 CBCT 衍生膀胱体积平均值为 2.41cm3(SD,3.97cm3)。CBCT 膀胱/PTV 体积与计划 CT 对照明显不同(p=0.047)。

结论

在本试验中,患者的膀胱和 PTV 体积和位置发生了显著变化。