Yuan Huiming, Zhou Yuan, Zhang Lihua, Liang Zhen, Zhang Yukui
Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R.&A. Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023, China.
J Chromatogr A. 2009 Oct 30;1216(44):7478-82. doi: 10.1016/j.chroma.2009.06.019. Epub 2009 Jun 10.
An integrated platform with the combination of proteins and peptides separation was established via the unit of on-line proteins digestion, by which proteins were in sequence separated by column switch recycling size exclusion chromatography (csrSEC), on-line digested by an immobilized trypsin microreactor, trapped and desalted by two parallel C8 precolumns, separated by microRPLC with the linear gradient of organic modifier concentration, and identified by ESI-MS/MS. A 6-protein mixture, with Mr ranging from 10 kDa to 80 kDa, was used to evaluate the performance of the integrated platform, and all proteins were identified with sequence coverage over 5.67%. Our experimental results demonstrate that such an integrated platform is of advantages such as good time compatibility, high peak capacity, and facile automation, which might be a promising approach for proteome study.
通过在线蛋白质消化单元建立了一个蛋白质和肽分离相结合的集成平台,利用该平台,蛋白质依次通过柱切换循环尺寸排阻色谱(csrSEC)进行分离,通过固定化胰蛋白酶微反应器进行在线消化,由两个平行的C8预柱进行捕集和脱盐,通过有机改性剂浓度线性梯度的微RPLC进行分离,并通过ESI-MS/MS进行鉴定。使用一种分子量范围为10 kDa至80 kDa的6种蛋白质混合物来评估该集成平台的性能,所有蛋白质的序列覆盖率均超过5.67%。我们的实验结果表明,这样一个集成平台具有时间兼容性好、峰容量高和易于自动化等优点,这可能是蛋白质组学研究的一种有前途的方法。