Suppr超能文献

采用单四极杆质谱仪对可卡因、苯甲酰古柯碱和古柯碱甲酯的鉴定点系统适应性进行研究。

Investigation of the identification point system adaptation in cocaine, benzoylecgonine and ecgonine methyl ester using a single quadrupole mass spectrometer.

机构信息

Laboratory of Forensic Medicine and Toxicology, Medical School, University of Athens, Greece.

出版信息

Rapid Commun Mass Spectrom. 2009 Dec;23(23):3772-80. doi: 10.1002/rcm.4312.

Abstract

At present, no official criteria exist for drug identification using single quadrupole mass spectrometers although the European Union (EU) criteria for compound identification have been adopted. These criteria are evaluated with respect to the confirmation of cocaine and its metabolites by single quadrupole liquid chromatography/mass spectrometry (LC/MS) and problems are highlighted. Spiked samples, proficiency testing samples, certified reference materials and samples from real cases that had screened positive for cocaine derivatives by immunoassay were subjected to confirmation by LC/MS using single ion monitoring with in-source fragmentation. The EU criteria for compound identification were applied for the confirmation of cocaine, benzoylecgonine and ecgonine methyl ester. The use of the identification point (IP) system in spiked, proficiency testing samples and certified reference materials provided acceptable results in all cases while in some cases real positive samples did not provide acceptable results. Failure to meet the EU criteria was attributed to low fragmentation at the lower concentrations and the ion suppression effect while both factors affected compliance with the IP system. The identification of cocaine and its metabolites was considerably improved by using a combination of ammonium formate and formic acid as the LC mobile phase. It appears that poor in-source fragmentation in single quadrupole LC/MS and ion suppression may constitute a problem with drug identification when implementing the IP system in real samples, resulting in false negative results. Further investigation is needed for the use of such IP systems to be suitable for use in LC/MS methods.

摘要

目前,虽然采用了欧盟(EU)化合物鉴定标准,但仍没有用于单四极杆质谱仪进行药物鉴定的官方标准。这些标准是根据单四极杆液相色谱/质谱(LC/MS)对可卡因及其代谢物的确认进行评估的,并强调了其中的问题。对加标样品、能力验证样品、有证参考物质以及通过免疫测定筛选可卡因衍生物呈阳性的实际案例样品进行了 LC/MS 分析,采用源内碎裂的单离子监测法进行确认。可卡因、苯甲酰古柯碱和古柯碱甲酯的化合物鉴定采用了欧盟的鉴定点(IP)系统标准。在加标、能力验证和有证参考物质中使用鉴定点系统,在所有情况下都能得到可接受的结果,但在某些情况下,实际阳性样品的结果却不可接受。未达到欧盟标准是因为在较低浓度下碎裂程度低和离子抑制效应,这两个因素都影响了对 IP 系统的遵守。通过使用甲酸铵和甲酸作为 LC 流动相,可卡因及其代谢物的鉴定得到了显著改善。在实际样品中实施 IP 系统时,单四极杆 LC/MS 中较差的源内碎裂和离子抑制可能构成药物鉴定的问题,导致假阴性结果。需要进一步研究此类 IP 系统在 LC/MS 方法中的适用性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验