Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography.

机构信息

Department of Radiology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki City, Osaka 569-8686, Japan.

出版信息

Acad Radiol. 2010 Feb;17(2):207-11. doi: 10.1016/j.acra.2009.09.010. Epub 2009 Nov 17.

Abstract

RATIONALE AND OBJECTIVES

To investigate the feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in computed tomography coronary angiography (CTCA) using a 320-detector row scanner.

MATERIALS AND METHODS

Ninety-eight patients who underwent CTCA in a single heartbeat with electrocardiogram-gating were divided into two groups, receiving 0.8 mL/kg of contrast material injected at a fixed duration of 12 seconds (A; n = 48) or 0.7 mL/kg of contrast material injected at a fixed duration of 10 seconds (B; n = 50); all patients then received 20 mL of saline. Contrast densities were assessed for the ascending aorta, left ventricle, right coronary artery (RCA), and left main coronary artery (LMA).

RESULTS

The mean flow rate was 4.00 + or - 0.56 mL/second in group A and 4.06 + or - 0.57 mL/second in group B (P = .51). There were no significant differences in the mean enhancement values of the ascending aorta, LMA and proximal RCA between the two groups. Also, there was no significant difference between the mean enhancement values at the three different levels of the RCA (proximal, middle, and distal segments) (group A; P = .27, group B; P = .07).

CONCLUSION

The use of 0.7 mL/kg of contrast material injected at a fixed duration of 10 seconds was feasible for CTCA using 320-detector row CT, with a sufficient and reliable contrast enhancement in the ascending aorta and coronary artery.

摘要

背景与目的

使用 320 排探测器 CT 机,通过体质量适应性碘剂量方案行低容量对比剂注射,探讨单次心跳心电门控冠状动脉 CT 血管成像(CTCA)中应用的可行性。

材料与方法

98 例行单次心跳 CTCA 患者,应用心电门控,随机分为两组,A 组(n = 48),采用 0.8 mL/kg 对比剂,注射时间 12 秒;B 组(n = 50),采用 0.7 mL/kg 对比剂,注射时间 10 秒,均使用 20 mL 生理盐水。评估升主动脉、左心室、右冠状动脉(RCA)和左主干冠状动脉(LMA)的对比剂密度。

结果

A 组和 B 组平均流速分别为 4.00 ± 0.56 mL/秒和 4.06 ± 0.57 mL/秒(P =.51)。两组升主动脉、LMA 和 RCA 近端的平均强化值差异无统计学意义。RCA 三个不同节段(近段、中段和远段)的平均强化值也无统计学差异(A 组:P =.27;B 组:P =.07)。

结论

在 320 排探测器 CT 机上应用体质量适应性碘剂量方案,0.7 mL/kg 对比剂,注射时间 10 秒,升主动脉和冠状动脉可获得充分且可靠的强化。