Division of Cardiology, Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Korean Circ J. 2009 Apr;39(4):157-62. doi: 10.4070/kcj.2009.39.4.157. Epub 2009 Apr 28.
The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT).
In 20 patients (mean age, 50+/-12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitral valves) were evaluated using MDCT. We selected images vertical and parallel to the mechanical valve. The valve orifice area (OA) and valve length were determined by manual tracing and the opening and closing angles were measured using a protractor. The OA and length of the mechanical valves were compared with the manufacturer's values.
The geometric orifice areas (GOAs) based on the manufacturer's values and the OAs determined by MDCT were 3.4+/-0.2 cm(2) and 3.4+/-0.3 cm(2) for the mitral valves and 2.1+/-0.3 cm(2) and 2.1+/-0.4 cm(2) for the aortic valves, respectively. The correlation coefficients between the OA measures were 0.433 for the mitral valves and 0.874 for the aortic valves (both p<0.001). The lengths based on the manufacturer's values and determined by MDCT were 29.3+/-1.99 mm and 29.6+/-1.65 mm for the mitral valves and 21.5+/-2.1 mm and 20.7+/-2.3 mm for the aortic valves, respectively. The correlation coefficients between the measures were 0.651 for the mitral valve and 0.846 for the aortic valve (both p<0.001). The opening and closing angles determined by MDCT were 10.9+/-0.6 degrees and 131.1+/-3.2 degrees for the mitral valves and 11.1+/-0.9 degrees and 120.6+/-1.7 degrees for the aortic valves, respectively.
MDCT is an accurate modality with which to assess the function and morphology of bileaflet mechanical valves.
本研究旨在使用 64 层多排螺旋 CT(MDCT)评估机械瓣膜功能。
在 20 例患者(平均年龄 50+/-12 岁;男女比 10:10)中,使用 MDCT 评估了 30 个 St. Jude 双叶机械瓣膜(15 个主动脉瓣和 15 个二尖瓣)。我们选择垂直和平行于机械瓣膜的图像。通过手动追踪确定瓣口面积(OA)和瓣膜长度,并使用量角器测量开闭角度。比较机械瓣膜的 OA 和长度与制造商的值。
基于制造商值的几何瓣口面积(GOA)和 MDCT 确定的瓣口面积分别为二尖瓣的 3.4+/-0.2cm²和 3.4+/-0.3cm²,主动脉瓣的 2.1+/-0.3cm²和 2.1+/-0.4cm²。二尖瓣的 OA 测量值之间的相关系数为 0.433,主动脉瓣的相关系数为 0.874(均<0.001)。基于制造商值和 MDCT 确定的长度分别为二尖瓣的 29.3+/-1.99mm 和 29.6+/-1.65mm,主动脉瓣的 21.5+/-2.1mm 和 20.7+/-2.3mm。二尖瓣的测量值之间的相关系数为 0.651,主动脉瓣的相关系数为 0.846(均<0.001)。MDCT 确定的开闭角度分别为二尖瓣的 10.9+/-0.6 度和 131.1+/-3.2 度,主动脉瓣的 11.1+/-0.9 度和 120.6+/-1.7 度。
MDCT 是一种评估双叶机械瓣膜功能和形态的准确方法。