Suppr超能文献

架空输电线上的电晕离子:对直流电场和环境粒子浓度水平的影响。

Corona ions from overhead transmission voltage powerlines: effect on direct current electric field and ambient particle concentration levels.

机构信息

ILAQH, School of Engineering Systems, and School of Mathematical Sciences, Queensland University of Technology Brisbane, GPO Box 2434, Brisbane 4001, Australia.

出版信息

Environ Sci Technol. 2010 Jan 1;44(1):526-31. doi: 10.1021/es9024063.

Abstract

Along with their essential role in electricity transmission and distribution, some powerlines also generate large concentrations of corona ions. This study aimed at the comprehensive investigation of corona ions, vertical direct current electric field (dc e-field), ambient aerosol particle charge, and particle number concentration levels in the proximity of some high/subtransmission voltage powerlines. The influence of meteorology on the instantaneous value of these parameters and the possible existence of links or associations between the parameters measured were also statistically investigated. The presence of positive and negative polarities of corona ions was associated with variation in the mean vertical dc e-field, ambient ion, and particle charge concentration level. Though these variations increased with wind speed, their values also decreased with distance from the powerlines. Predominately positive polarities of ions were recorded up to a distance of 150 m (with the maximum values recorded 50 m downwind of the powerlines). At 200 m from the source, negative ions predominated. Particle number concentration levels, however, remained relatively constant (10(3) particle cm(-3)), irrespective of the sampling site and distance from the powerlines. Meteorological factors of temperature, humidity, and wind direction showed no influence on the electrical parameters measured. The study also discovered that e-field measurements were not necessarily a true representation of the ground-level ambient ion/particle charge concentrations.

摘要

除了在输配电中发挥重要作用外,一些电力线还会产生大量的电晕离子。本研究旨在全面调查一些高压/超高压电力线附近的电晕离子、垂直直流电场 (dc e-field)、环境气溶胶粒子电荷和粒子数浓度水平。气象条件对这些参数瞬时值的影响,以及所测量参数之间是否存在联系或关联,也进行了统计调查。电晕离子的正、负极性与平均垂直 dc e-field、环境离子和粒子电荷浓度水平的变化有关。尽管这些变化随风速的增加而增加,但它们的值也随与电力线的距离的增加而减小。在距离电力线 150 m 范围内(记录到的最大值在电力线下风 50 m 处),主要记录到正极性离子。在离源 200 m 处,负离子占主导地位。然而,颗粒数浓度水平保持相对稳定(10(3)个颗粒 cm(-3)),与采样地点和与电力线的距离无关。温度、湿度和风向等气象因素对所测量的电气参数没有影响。该研究还发现,电场测量不一定能真实反映地面环境离子/粒子电荷浓度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验