Suppr超能文献

7T 下犬脑的磁共振成像

Magnetic resonance imaging of the canine brain at 7 T.

作者信息

Kang Byeong-Teck, Ko Ki-Jin, Jang Dong-Pyo, Han Jae-Yong, Lim Chae-Young, Park Chul, Yoo Jong-Hyun, Kim Ju-Won, Jung Dong-In, Kim Young-Bo, Woo Eung-Je, Cho Zang-Hee, Park Hee-Myung

机构信息

BK21 Program of Basic & Diagnostic Veterinary Specialist Program for Animal Diseases and Department of Veterinary Internal Medicine, Konkuk University, Seoul, South Korea.

出版信息

Vet Radiol Ultrasound. 2009 Nov-Dec;50(6):615-21. doi: 10.1111/j.1740-8261.2009.01591.x.

Abstract

The purpose of this study was to describe relevant canine brain structures as seen on T2-weighted images following magnetic resonance (MR) imaging at 7 T and to compare the results with imaging at 1.5 T. Imaging was performed on five healthy laboratory beagle dogs using 1.5 and 7 T clinical scanners. At 1.5 T, spin echo images were acquired, while gradient echo images were acquired at 3 T. Image quality and conspicuity of anatomic structures were evaluated qualitatively by direct comparison of the images obtained from the two different magnetic fields. The signal-to-nose ratio (SNR) and contrast-to-noise ratio (CNR) were calculated and compared between 1.5 and 7 T. The T2-weighted images at 7 T provided good spatial and contrast resolution for the identification of clinically relevant brain anatomy; these images provided better delineation and conspicuity of the brain stem and cerebellar structures, which were difficult to unequivocally identify at 1.5 T. However, frontal and parietal lobe and the trigeminal nerve were difficult to identify at 7 T due to susceptibility artifact. The SNR and CNR of the images at 7 T were significantly increased up to 318% and 715% compared with the 1.5 T images. If some disadvantages of 7 T imaging, such as susceptibility artifacts, technical difficulties, and high cost, can be improved, 7 T clinical MR imaging could provide a good experimental and diagnostic tool for the evaluation of canine brain disorders.

摘要

本研究的目的是描述在7T磁共振成像(MR)后T2加权图像上所见的相关犬脑结构,并将结果与1.5T成像进行比较。使用1.5T和7T临床扫描仪对五只健康的实验比格犬进行成像。在1.5T时采集自旋回波图像,而在3T时采集梯度回波图像。通过直接比较从两个不同磁场获得的图像,定性评估图像质量和解剖结构的清晰度。计算并比较了1.5T和7T之间的信噪比(SNR)和对比噪声比(CNR)。7T时的T2加权图像为识别临床上相关的脑解剖结构提供了良好的空间和对比分辨率;这些图像能更好地描绘脑干和小脑结构,而这些结构在1.5T时难以明确识别。然而,由于敏感性伪影,额叶、顶叶和三叉神经在7T时难以识别。与1.5T图像相比,7T图像的SNR和CNR显著提高,分别高达318%和715%。如果7T成像的一些缺点,如敏感性伪影、技术困难和高成本等能够得到改善,7T临床MR成像可为评估犬脑疾病提供良好的实验和诊断工具。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验