文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

超声造影剂剂量对聚焦超声诱导的血脑屏障破坏持续时间的影响。

Effect of ultrasound contrast agent dose on the duration of focused-ultrasound-induced blood-brain barrier disruption.

机构信息

Department of Biomedical Imaging and Radiological Sciences, School of Biomedical Science and Engineering, National Yang-Ming University, 11221 Taipei, Taiwan.

出版信息

J Acoust Soc Am. 2009 Dec;126(6):3344-9. doi: 10.1121/1.3242376.


DOI:10.1121/1.3242376
PMID:20000948
Abstract

It has been shown that focused ultrasound (FUS) is capable of noninvasive and reversible disruption of the blood-brain barrier (BBB) at target regions when applied in the presence of ultrasound contrast agent (UCA). The purpose of this study was to investigate the effects of UCA dose on the reversibility of BBB disruption induced by the same acoustical power of FUS. Sonications were applied at an ultrasound frequency of 1 MHz with a 5% duty cycle and a repetition frequency of 1 Hz. The brains of 66 male Sprague-Dawley rats were subjected to sonications with three doses of UCA. BBB integrity was evaluated via femoral vein injection of Evans Blue (EB) while the rats were anesthetized. The relationship between UCA dose and the region of EB extravasation was evaluated at an acoustic power of 1.43 W. The BBB disruption, as indexed by the amount of EB extravasation, was the largest immediately after the sonications. The quantity of Evans blue extravasation decreased as a function of time at various UCA doses. This study demonstrates that the appropriate dose of UCA not only enhance the BBB opening but also effectively aid in controlling the duration of BBB disruption.

摘要

已有研究表明,在超声对比剂(UCA)存在的情况下,聚焦超声(FUS)能够在靶区无创且可逆地破坏血脑屏障(BBB)。本研究旨在探讨不同剂量的 UCA 对 FUS 相同声功率致 BBB 破坏的可逆性的影响。声处理采用 1MHz 超声频率、5%占空比和 1Hz 重复频率。66 只雄性 Sprague-Dawley 大鼠的大脑接受了三种剂量 UCA 的声处理。当大鼠处于麻醉状态时,通过股静脉注射 Evans Blue(EB)来评估 BBB 的完整性。在 1.43W 的声功率下,评估了 UCA 剂量与 EB 外渗区域之间的关系。以 EB 外渗量为指标的 BBB 破坏在声处理后即刻最大。在不同 UCA 剂量下,EB 外渗的量随时间呈下降趋势。本研究表明,适当剂量的 UCA 不仅能增强 BBB 开放,而且能有效控制 BBB 破坏的持续时间。

相似文献

[1]
Effect of ultrasound contrast agent dose on the duration of focused-ultrasound-induced blood-brain barrier disruption.

J Acoust Soc Am. 2009-12

[2]
Reversible blood-brain barrier disruption by repeated transcranial focused ultrasound allows enhanced extravasation.

J Control Release. 2010-11-8

[3]
Efficiency of drug delivery enhanced by acoustic pressure during blood-brain barrier disruption induced by focused ultrasound.

Int J Nanomedicine. 2012-5-23

[4]
Quantitative evaluation of focused ultrasound with a contrast agent on blood-brain barrier disruption.

Ultrasound Med Biol. 2007-9

[5]
Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption.

Ultrason Sonochem. 2008-4

[6]
Evaluation of dose distribution of molecular delivery after blood-brain barrier disruption by focused ultrasound with treatment planning.

Ultrasound Med Biol. 2013-2-4

[7]
Prenatal exposure to diagnostic ultrasound impacts blood-brain barrier permeability in rats.

Ultrasound Med Biol. 2012-3-15

[8]
Pulse sequence and timing of contrast-enhanced MRI for assessing blood-brain barrier disruption after transcranial focused ultrasound in the presence of hemorrhage.

J Magn Reson Imaging. 2010-6

[9]
Focused ultrasound-mediated noninvasive blood-brain barrier modulation: preclinical examination of efficacy and safety in various sonication parameters.

Neurosurg Focus. 2018-2

[10]
Pulsed high-intensity focused ultrasound enhances the relative permeability of the blood-tumor barrier in a glioma-bearing rat model.

IEEE Trans Ultrason Ferroelectr Freq Control. 2011-5

引用本文的文献

[1]
Focused Ultrasound Combined with Microbubbles in Central Nervous System Applications.

Pharmaceutics. 2021-7-15

[2]
Neuro-Nano Interfaces: Utilizing Nano-Coatings and Nanoparticles to Enable Next-Generation Electrophysiological Recording, Neural Stimulation, and Biochemical Modulation.

Adv Funct Mater. 2018-3-21

[3]
Diffusion Tensor Imaging and Chemical Exchange Saturation Transfer MRI Evaluation on the Long-Term Effects of Pulsed Focused Ultrasound and Microbubbles Blood Brain Barrier Opening in the Rat.

Front Neurosci. 2020-8-25

[4]
Therapeutic Potentials of Localized Blood-Brain Barrier Disruption by Noninvasive Transcranial Focused Ultrasound: A Technical Review.

J Clin Neurophysiol. 2020-3

[5]
Effects of Focused-Ultrasound-and-Microbubble-Induced Blood-Brain Barrier Disruption on Drug Transport under Liposome-Mediated Delivery in Brain Tumour: A Pilot Numerical Simulation Study.

Pharmaceutics. 2020-1-15

[6]
Evaluating the safety profile of focused ultrasound and microbubble-mediated treatments to increase blood-brain barrier permeability.

Expert Opin Drug Deliv. 2019-1-29

[7]
Targeting Effects on the Volume of the Focused Ultrasound-Induced Blood-Brain Barrier Opening in Nonhuman Primates In Vivo.

IEEE Trans Ultrason Ferroelectr Freq Control. 2017-3-13

[8]
Focused Ultrasound-Induced Blood-Brain Barrier Opening: Association with Mechanical Index and Cavitation Index Analyzed by Dynamic Contrast-Enhanced Magnetic-Resonance Imaging.

Sci Rep. 2016-9-15

[9]
Noninvasive and targeted delivery of therapeutics to the brain using focused ultrasound.

Neuropharmacology. 2017-7-1

[10]
Noninvasive, Targeted, and Non-Viral Ultrasound-Mediated GDNF-Plasmid Delivery for Treatment of Parkinson's Disease.

Sci Rep. 2016-1-20

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索