PURPOSE

LigaSure (ValleyLab, CO, USA) is a bipolar diathermy system that seals vessels with reduced thermal spread. The device has been used successfully in abdominal surgery and has been introduced as a new method for hemostasis during thyroidectomy. This study compares the efficacy and advantages of LigaSure, when used for thyroidectomy in benign nodular thyroid disease, with the conventional clamp-and-tie technique.

METHODS

Between December 2003 and December 2008, 410 patients underwent thyroid surgery (333 with the conventional clamp-and-tie technique and 77 with LigaSure). Nine patients did not sign the ethical approval document and so were excluded from the study; the results of 68 LigaSure patients were evaluated. The main outcomes measured were age, sex, operating time, postoperative hypocalcemia, recurrent laryngeal nerve palsy, and drain use. Statistical analysis consisted of the chi-squared test and Student's t-test.

RESULTS

The mean operating time was significantly shorter in the LigaSure group by 24.1+/-1.7 minutes for a total thyroidectomy (P<0.0001) and 7.6+/-0.1 minutes for one side total plus other side sub- total thyroidectomy (P<0.0001). Bleeding during surgery was significantly lower in the LigaSure group (P<0.0001). There were no significant differences between the study groups in terms of postoperative hypoparathyroidism, recurrent laryngeal nerve palsy, and postthyroidectomy hemorrhage.

CONCLUSION

The LigaSure vessel sealer is a safe, effective alternative for thyroid surgery that reduces the overall operating time. However, its higher cost is a significant handicap for its use in surgery in developing countries.

摘要

目的

LigaSure(美国 ValleyLab,CO)是一种双极电凝系统,可减少热扩散来封闭血管。该设备已成功应用于腹部手术,并已被引入甲状腺切除术的止血新方法。本研究比较了 LigaSure 在治疗良性结节性甲状腺疾病中的疗效和优势,与传统的夹闭和结扎技术。

方法

2003 年 12 月至 2008 年 12 月,410 例患者接受了甲状腺手术(333 例采用传统夹闭和结扎技术,77 例采用 LigaSure)。有 9 例患者未签署伦理批准文件,因此被排除在研究之外;对 68 例 LigaSure 患者的结果进行了评估。主要观察指标为年龄、性别、手术时间、术后低钙血症、喉返神经麻痹和引流管使用。统计分析包括卡方检验和学生 t 检验。

结果

LigaSure 组的总甲状腺切除术的平均手术时间明显缩短 24.1+/-1.7 分钟(P<0.0001),单侧全甲状腺切除加对侧次全甲状腺切除术的平均手术时间明显缩短 7.6+/-0.1 分钟(P<0.0001)。LigaSure 组术中出血明显减少(P<0.0001)。两组间术后甲状旁腺功能减退、喉返神经麻痹和甲状腺切除术后出血无显著差异。

结论

LigaSure 血管密封器是一种安全有效的甲状腺手术替代方法,可缩短总手术时间。然而,其较高的成本是其在发展中国家手术中应用的一个显著障碍。