Suppr超能文献

Significant discrepancy in cyclosporin A post-dose concentrations when analyzed with specific RIA and HPLC method.

作者信息

Grundmann M, Perinova I, Brozmanova H, Koristkova B, Safarcik K

机构信息

Department of Clinical Pharmacology, Ostrava University Hospital and Faculty of Health Studies, University of Ostrava, 708 52 Ostrava, Czech Republic.

出版信息

Int J Clin Pharmacol Ther. 2010 Feb;48(2):87-92. doi: 10.5414/cpp48087.

Abstract

C(2) or AUC sparse sampling methods are widely recommended for therapeutic monitoring of cyclosporin A (CsA). One additional reason for promoting the C(2) sampling time in place of commonly used C(0) is that the C(2) level may actually provide more accurate measurement of parent drug concentration by immunoassays, as lower portion of metabolites has been formed 2 hours post-dose than at the steady-state trough time point. HPLC and RIA whole blood levels of CsA and its main metabolites AM1, AM9 and AM4N were compared during 12 hours profile after chronic administration. 40 stable renal transplant male patients (age 49 +/- 6 years, body weight 76 +/- 7 kg) were treated with CsA (Sandimmun Neoral, Novartis s.r.o, Prague, Czech Republic) in doses 198 +/- 56 mg twice daily. Samples were collected in steady state (after 2 weeks of regular treatment regimen) as follows: pre-dose, 0.5, 1, 1.5, 2, 3, 5, 8 and 12 hours after dose. CsA concentrations were determined both specific RIA assay (Cyclo-Trac SP Whole, Dia Sorin) and HPLC method, where concentrations of metabolites AM1, AM9 and AM4N were simultaneously analyzed. The AUC(0-12) was calculated by the linear trapezoidal rule. The percentage prediction error defined as [(RIA value-HPLC value)/HPLC value] x 100 was used for estimation of differences. C(max), t(max), and C(avg) were compared using Student's t-test. RIA produced significantly higher CsA levels than HPLC method in the period of 0.5 - 5 hours after application. The greatest differences (43 - 56%) occurred between 1 and 3 hours after dose. AUC(0-12), C(max) a C(avg) calculated from RIA results were consequently significantly higher. Only t(max) remained unchanged. The ratio of metabolites/parent drug after CsA intake is decreasing but their absolute concentrations are significantly increasing. Mean levels at C(0)/C(2) were CsA-RIA 82/612, CsA-HPLC 89/425, AM1 121/179, AM9 4.1/81.4, AM4N 9.5/21.0 ng/ml. TDM using C(2) and AUC sparse sampling may cause misleading interpretation using both methods alternately for the same patient.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验