Department of Otolaryngology, University of Florida, Gainesville, FL 32610-0264, USA.
Otolaryngol Head Neck Surg. 2010 Mar;142(3):405-8. doi: 10.1016/j.otohns.2009.11.009. Epub 2010 Jan 8.
Carbomethylcellulose (CMC) foam has been widely adopted to promote hemostasis and healing in sinus surgery. There has been interest in the use of CMC in middle ear surgery. The purpose of this study was to evaluate the safety and efficacy of CMC foam for use in middle ear surgery.
Prospective, controlled.
Academic research laboratory.
Adult guinea pigs underwent experimental tympanoplasty followed by packing of the middle ear (n = 19 per group) with CMC, hyaluronic acid (HA), or gelatin sponge (GS). Auditory evoked brainstem response testing and otomicroscopy were performed before and serially for eight weeks after surgery. Tympanic membrane healing, hemostasis, and retention of packing material were assessed.
All tympanic membranes treated with CMC healed by week eight. Less postoperative bleeding was observed with CMC than with HA or GS. Surgery elevated auditory thresholds, at least temporarily, in all groups. However, CMC was associated with greater auditory threshold elevation (15-25 dB) at eight weeks across all test frequencies relative to HA or GS (P < 0.01). Residual CMC and scarring were not found in the middle ear, indicating that the hearing loss was sensorineural. No head tilt posturing suggestive of vestibulopathy was seen.
CMC was associated with hearing loss and may be ototoxic. Therefore, CMC should not be used in human middle ears given the presence of several nontoxic alternative materials.
羧甲基纤维素(CMC)泡沫已广泛用于促进鼻窦手术中的止血和愈合。人们对 CMC 在中耳手术中的应用产生了兴趣。本研究旨在评估 CMC 泡沫在中耳手术中的安全性和有效性。
前瞻性、对照研究。
学术研究实验室。
成年豚鼠接受实验性鼓室成形术,随后用 CMC、透明质酸(HA)或明胶海绵(GS)填充中耳(每组 n = 19)。在手术前和手术后八周内进行听觉诱发脑干反应测试和耳镜检查。评估鼓膜愈合、止血和填塞材料的保留情况。
所有用 CMC 治疗的鼓膜在第八周愈合。与 HA 或 GS 相比,用 CMC 观察到的术后出血较少。所有组的手术均暂时升高了听觉阈值。然而,与 HA 或 GS 相比,CMC 在所有测试频率下在第八周时与更大的听觉阈值升高(15-25 dB)相关(P < 0.01)。中耳中未发现残留的 CMC 和瘢痕,表明听力损失是感音神经性的。未发现提示前庭病的头部倾斜姿势。
CMC 与听力损失有关,并且可能具有耳毒性。因此,鉴于存在几种非毒性替代材料,不应将 CMC 用于人类中耳。