Lee Ik-Jae, Yu Chung-Jong, Yun Young-Duck, Lee Chae-Soon, Seo In Deuk, Kim Hyo-Yun, Lee Woul-Woo, Chae Keun Hwa
Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 790-784, South Korea.
Rev Sci Instrum. 2010 Feb;81(2):026103. doi: 10.1063/1.3298581.
A new hard x-ray beamline, 10B KIST-PAL beamline (BL10B), has been designed and constructed at the Pohang Light Source (PLS) in Korea. The beamline, operated by Pohang Accelerator Laboratory-Korean Institute of Science and Technology consortium, is dedicated to x-ray scattering (XRS) and x-ray absorption fine structure (XAFS) experiments. X rays with photon energies from 4.0 to 16.0 keV are delivered to the experimental station passing a collimating mirror, a fixed-exit double-crystal Si(111) monochromator, and a toroidal mirror. Basic experimental equipment for XAFS measurement, a high resolution diffractometry, an image plate detector system, and a hot stage have been prepared for the station. From our initial commissioning and performance testing of the beamline, it is observed that BL10B beamline can perform XRS and XAFS measurements successfully.
韩国浦项光源(PLS)设计并建造了一条新的硬X射线光束线——10B KIST-PAL光束线(BL10B)。该光束线由浦项加速器实验室-韩国科学技术研究院联合运营,专门用于X射线散射(XRS)和X射线吸收精细结构(XAFS)实验。光子能量在4.0至16.0 keV之间的X射线通过准直镜、固定出口双晶Si(111)单色仪和环形镜后传输到实验站。该实验站已配备了用于XAFS测量的基本实验设备、高分辨率衍射仪、成像板探测器系统和热台。从我们对该光束线的初步调试和性能测试中可以观察到,BL10B光束线能够成功进行XRS和XAFS测量。