Arthrodesis of the proximal interphalangeal joint in the horse: a cyclic biomechanical comparison of two and three parallel cortical screws inserted in lag fashion.

作者信息

Carmalt James L, Delaney Lana, Wilson David G

机构信息

Department of Large Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada.

出版信息

Vet Surg. 2010 Jan;39(1):91-4. doi: 10.1111/j.1532-950X.2009.00614.x.

Abstract

OBJECTIVE

To compare the biomechanical cyclic fatigue properties of 2 and 3 parallel transarticular 5.5 mm cortical screws used in arthrodesis of the proximal interphalangeal (PIP) joint.

STUDY DESIGN

Randomized block design, for horse, fixation method (2 versus three 5.5 mm cortical screws), side (right, left) and end (front, hind) in cadaveric equine limbs.

SAMPLE POPULATION

Cadaveric adult equine fore- and hindlimbs (n=5 pairs each).

METHODS

Two parallel 5.5 mm cortical screws were inserted in lag fashion, transarticularly through the PIP joint in 1 limb of a pair, and in the contralateral limb, three 5.5 mm cortical screws were inserted in similar fashion. Constructs were then tested in 3-point bending in a dorsal-to-palmar (plantar) direction using a materials testing machine using a cyclic load of -500 to -3500 N at a rate of 6 Hz.

RESULTS

There was no significant difference in displacement at failure, force at failure or number of cycles between limbs. Forelimb constructs tended to fail at a greater mean displacement than hindlimb constructs but this difference was not significant (P=.06). There was no statistical difference in any tested biomechanical variable between left- and right-sided limbs.

CONCLUSIONS

There was no significant difference in the number of cycles to failure for the 2 methods tested.

CLINICAL RELEVANCE

Two 5.5 mm cortical screws inserted in parallel for PIP joint arthrodesis is surgically simpler, results in comparable biomechanical performance in the current model and should perform as well as three 5.5 mm screws under cyclic fatigue conditions.

摘要

目的

比较用于近节指间关节(PIP)关节融合术的2枚和3枚平行的5.5毫米皮质骨螺钉的生物力学循环疲劳特性。

研究设计

随机区组设计,用于马的尸体肢体,固定方法(2枚与3枚5.5毫米皮质骨螺钉)、侧别(右、左)和端部(前肢、后肢)。

样本群体

成年马的尸体前肢和后肢(各n = 5对)。

方法

在一对肢体的1个肢体中以拉力方式经PIP关节平行插入2枚5.5毫米皮质骨螺钉,在对侧肢体中以类似方式插入3枚5.5毫米皮质骨螺钉。然后使用材料试验机在背侧至掌侧(跖侧)方向进行三点弯曲测试,使用-500至-3500 N的循环载荷,频率为6 Hz。

结果

各肢体在失效时的位移、失效时的力或循环次数方面无显著差异。前肢结构在失效时的平均位移往往比后肢结构大,但这种差异不显著(P = 0.06)。左右侧肢体之间在任何测试的生物力学变量上均无统计学差异。

结论

所测试的2种方法在失效循环次数上无显著差异。

临床意义

用于PIP关节融合术平行插入的2枚5.5毫米皮质骨螺钉手术操作更简单,在当前模型中生物力学性能相当,在循环疲劳条件下应与3枚5.5毫米螺钉表现相同。