Suppr超能文献

无眼球眼眶的一期和二期植入物。术前和术后计算机断层扫描表现。

Primary and secondary implants in the anophthalmic orbit. Preoperative and postoperative computed tomographic appearance.

作者信息

Smit T J, Koornneef L, Zonneveld F W, Groet E, Otto A J

机构信息

Department of Ophthalmology, University of Amsterdam, The Netherlands.

出版信息

Ophthalmology. 1991 Jan;98(1):106-10. doi: 10.1016/s0161-6420(91)32351-0.

Abstract

Sagittal computed tomographic (CT) scans of 10 anophthalmic orbits with a primary implant, an acrylic ball covered with donor sclera, and 10 anophthalmic orbits before and after insertion of a secondary implant were studied. For each patient, the scans of the anophthalmic and contralateral normal orbit were compared. In the anophthalmic orbits, the anatomy was optimally restored in those with a primary implant, and suboptimal results were achieved in the orbits with a secondary implant. The greatest differences were noticed in the orbits without an implant. Differences were noticed for the position and length of the superior muscle complex and the inferior rectus muscle, the position of the upper eyelid, the depth of the superior sulcus, and the backward tilt of the prosthesis. The authors conclude that the rotatory displacement of the orbital contents after enucleation, which explains the sequelae of the anophthalmic orbit, is grossly circumvented by the insertion of an implant. In achieving this effect, primary implants are better than secondary ones.

摘要

对10例植入了覆盖供体巩膜的丙烯酸球的一期植入物的无眼球眼眶以及10例植入二期植入物前后的无眼球眼眶进行了矢状位计算机断层扫描(CT)研究。对每位患者,比较了无眼球眼眶和对侧正常眼眶的扫描结果。在无眼球眼眶中,植入一期植入物的眼眶解剖结构得到了最佳恢复,而植入二期植入物的眼眶则取得了次优结果。在没有植入物的眼眶中观察到的差异最大。在上直肌复合体和下直肌的位置和长度、上睑位置、上睑沟深度以及假体的向后倾斜方面都观察到了差异。作者得出结论,眼球摘除术后眼眶内容物的旋转移位解释了无眼球眼眶的后遗症,而植入物的插入可大大避免这种情况。在实现这一效果方面,一期植入物优于二期植入物。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验