通用样品制备和双极性液相色谱-飞行时间质谱法用于兴奋剂分析中的高通量筛选。

Generic sample preparation and dual polarity liquid chromatography-time-of-flight mass spectrometry for high-throughput screening in doping analysis.

机构信息

Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki, Finland.

出版信息

Drug Test Anal. 2009 Jun;1(6):250-66. doi: 10.1002/dta.50.

Abstract

The requirements on initial testing in doping control are getting tighter regarding efficiency and speed while the scope of analytes is getting more diverse and, consequently, the need for high-throughput methods is apparent. In this study, a comprehensive screening method for doping agents in human urine is presented, based on solid phase extraction (SPE) and liquid chromatography-time-of-flight mass spectrometry (LCTOFMS). The method covers most of the compound groups in the list of prohibited substances by World Anti-Doping Agency (WADA). Mixed-mode SPE on two types of sorbent and the use of negative ionization mode besides the commonly used positive mode in electrospray ionization (ESI) allowed detection of acidic compounds, such as sulpho-conjugated metabolites. A run time of 8 minutes for each of the two ESI polarities was achieved. The method was validated regarding relative ionization efficiency, selectivity and signal to noise at the WADA's minimum required performance limit (MRPL) level, resulting in the acceptance of 197 compounds. A selection of 20 compounds was submitted for a more thorough validation, including extraction recovery, repeatability and linearity. Recovery and linearity (R(2)) varied mainly between 83-115% and 0.78-0.99, respectively. Median values for repeatability at the MRPL and 10 x MRPL levels were below 20%. A mean and median mass accuracy of 1.2 and 0.80 mDa, respectively, was achieved. The present method represents at the moment the widest coverage of low molecular weight prohibited substances for the screening in sports, providing an approach for further rationalisation of the analytical work-flow in the doping control laboratories.

摘要

在兴奋剂控制的初始检测中,对效率和速度的要求越来越高,而分析物的范围也越来越多样化,因此需要高通量的方法。本研究提出了一种基于固相萃取(SPE)和液相色谱-飞行时间质谱(LCTOFMS)的人尿中兴奋剂综合筛查方法。该方法涵盖了世界反兴奋剂机构(WADA)禁用物质清单中的大多数化合物组。混合模式 SPE 两种类型的吸附剂和除电喷雾电离(ESI)常用的正离子模式外,还采用负离子模式,允许检测酸性化合物,如磺化代谢物。两种 ESI 极性的运行时间均为 8 分钟。该方法在 WADA 的最低性能要求(MRPL)水平下对相对电离效率、选择性和信噪比进行了验证,结果接受了 197 种化合物。选择了 20 种化合物进行更彻底的验证,包括提取回收率、重复性和线性。回收率和线性(R(2))主要在 83-115%和 0.78-0.99 之间变化。在 MRPL 和 10 x MRPL 水平下,重复性的中位数值低于 20%。平均和中位数质量精度分别为 1.2 和 0.80 mDa。目前的方法代表了目前运动中低分子量禁用物质筛查的最广泛覆盖范围,为兴奋剂控制实验室的分析工作流程的进一步合理化提供了一种方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验