Dept. of Prosthodontics, University of Sao Paulo, Bauru School of Dentistry, Rua Vivaldo Guimaraes 17-62, Bauru 17012120, Sao Paulo, Brazil.
J Dent. 2010 Sep;38(9):707-12. doi: 10.1016/j.jdent.2010.04.001. Epub 2010 Apr 9.
To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system. The research hypotheses tested were: (1) fatigue reliability and failure mode are similar for the ML and DF cusps; (2) failure mode of one cusp does not affect the failure of the other.
The average dimensions of a mandibular first molar crown were imported into CAD software; a tooth preparation was modelled by 1.5 mm marginal high reduction of proximal walls and occlusal surface by 2.0 mm. The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n=14) with porcelain veneer on a 0.5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation. The crowns were step-stress mouth motion fatigued with sliding (0.7 mm) a tungsten-carbide indenter of 6.25 mm diameter down on the inclines of either the DF or ML cusps. Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated.
Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps. SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF. Fractures originated from the contact area regardless of the cusp loaded.
No significant difference on fatigue reliability was observed between the DF compared to the ML cusp. Fracture of one cusp did not affect the other.
比较解剖学正确的氧化锆(Y-TZP)冠系统的远颊(DF)和近中舌(ML)牙尖的可靠性。检验的研究假设为:(1)ML 和 DF 牙尖的疲劳可靠性和失效模式相似;(2)一个牙尖的失效模式不会影响另一个牙尖的失效。
将下颌第一磨牙冠的平均尺寸导入 CAD 软件;通过 1.5 毫米的近中壁边缘高降低和 2.0 毫米的咬合面进行牙体预备模型制作。基于 CAD 的牙体预备通过滑动(0.7 毫米)用直径为 6.25 毫米的碳化钨压头在 DF 或 ML 牙尖的倾斜面上进行分步应力口内运动疲劳。使用 200 N 的使用应力和在 200 N 负载下完成 50000 次循环的任务可靠性为 50%的 Weibull 曲线计算使用水平概率。
在 200 N 下完成 50000 次循环任务的可靠性在测试牙尖之间没有差异。SEM 成像显示 ML 牙尖的贴面内有较大的内聚性失效,而 DF 牙尖的较小。无论加载的牙尖如何,断裂都起源于接触区域。
与 ML 牙尖相比,DF 牙尖的疲劳可靠性没有明显差异。一个牙尖的断裂不会影响另一个牙尖。