Suppr超能文献

[Coflex棘突间稳定系统与椎弓根螺钉植入对腰椎三维运动稳定性的影响]

[Effect of Coflex interspinous stabilization and vertebral arch pedicle screw implantation on the stability of three-dimensional motions of the lumbar spine].

作者信息

Mao Zhong-xuan, Jiang Jian-ming, Yan Hui-bo, Zhao Wei-dong, Wang Feng-long, Wu Yi, Li Yong

机构信息

Department of Orthopedics and Spinal Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, China.

出版信息

Nan Fang Yi Ke Da Xue Xue Bao. 2010 Apr;30(4):863-6.

Abstract

OBJECTIVE

To evaluate the effect of Coflex interspinous stabilization and vertebral arch pedicle screw implant on the stability and motion of the lumbar spine.

METHODS

The range of motion (ROM) of 6 fresh adult human cadaver lumbar spine specimens (L(1) approximately S(1)) was biomechanically tested in forward flexion/extension stretch, left/right lateral bending and left/right axial rotation. The ROM and neutral zone (NZ) of the segments L(2/3), L(3/4), and L(4/5) were measured and compared in 3 conditions, namely intact condition (a), rigid fixation of the segment L(4/5) with vertebral arch pedicle screw (b), and condition b plus L(3/4) stabilization with Coflex device (c).

RESULTS

The ROM of segment L(4/5) was significantly smaller in conditions b and c than in condition a in all the directions (P<0.05). The ROM of segment L(3/4) was significantly smaller in conditions a and c than in condition b in extension stretch (P<0.01), smaller in condition a than in conditions b and c in left/right lateral bending (P<0.01), and decreased significantly in the order of a<c<b in forward flexion stretch and left/right axial rotation (P<0.05). The ROM of segment L(2/3) was significantly smaller in conditions a and b than in condition c in extension stretch (P<0.01), but showed no significant differences between the 3 conditions in the other directions (P>0.05).

CONCLUSIONS

The ROM of the segment superior to the lumbar spine with rigid fixation increases in all the directions, but can be reduced with Coflex device implanted in the superior segment, which results in only increased ROM of the segment superior to Coflex device in extension stretch.

摘要

目的

评估Coflex棘突间稳定系统与椎弓根螺钉植入对腰椎稳定性及活动度的影响。

方法

对6具新鲜成人尸体腰椎标本(L₁至S₁)在向前屈伸、左右侧屈及左右轴向旋转时的活动度(ROM)进行生物力学测试。测量并比较L₂/₃、L₃/₄和L₄/₅节段在3种情况下的ROM及中性区(NZ),这3种情况分别为:完整状态(a)、L₄/₅节段用椎弓根螺钉进行刚性固定(b)以及情况b加用Coflex装置对L₃/₄节段进行稳定(c)。

结果

在所有方向上,L₄/₅节段在情况b和c时的ROM均显著小于情况a(P<0.05)。在伸展时,L₃/₄节段在情况a和c时的ROM显著小于情况b(P<0.01);在左右侧屈时,L₃/₄节段在情况a时的ROM小于情况b和c(P<0.01);在向前屈伸及左右轴向旋转时,L₃/₄节段的ROM按a<c<b的顺序显著减小(P<0.05)。在伸展时,L₂/₃节段在情况a和b时的ROM显著小于情况c(P<0.01),但在其他方向上,这3种情况之间无显著差异(P>0.05)。

结论

腰椎节段进行刚性固定后,其上方节段的ROM在所有方向上均增加,但在上方节段植入Coflex装置后ROM会减小,这仅导致Coflex装置上方节段在伸展时的ROM增加。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验