Gong Hyun Sik, Chung Moon Sang, Oh Joo Han, Lee Young Ho, Kim Sae Hoon, Baek Goo Hyun
Department of Orthopaedics, Hand and Upper Extremity Service, Seoul National University Bundang Hospital, Seongnam, Korea.
J Hand Surg Am. 2010 Jun;35(6):976-80. doi: 10.1016/j.jhsa.2010.03.004. Epub 2010 May 7.
The authors report a case of a patient with complex radial head and ulnar shaft fractures with an associated tear of the interosseous membrane, which failed to heal despite open reduction internal fixation of the ulna, a bipolar radial head replacement, and cross pinning of the distal radioulnar joint. This case demonstrates that failure of the interosseous membrane can occur even in a properly replaced bipolar radial head with adequate immobilization of the forearm and pinning of the distal radioulnar joint.