Suppr超能文献

An Algorithm for Applying Multiple Currents Using Voltage Sources in Electrical Impedance Tomography.

作者信息

Choi Myoung H, Kao Tzu-Jen, Isaacson David, Saulnier Gary J, Newell Jonathan C

机构信息

Department of Electrical and Electronics Engineering, Kangwon National University, Chunchon, Korea.(

出版信息

Int J Control Autom Syst. 2008 Jan 1;6(4):613-619.

Abstract

A method to produce a desired current pattern in a multiple-source EIT system using voltage sources is presented. Application of current patterns to a body is known to be superior to the application of voltage patterns in terms of high spatial frequency noise suppression, resulting in high accuracy in conductivity and permittivity images. Since current sources are difficult and expensive to build, the use of voltage sources to apply the current pattern is desirable. An iterative algorithm presented in this paper generates the necessary voltage pattern that will produce the desired current pattern. The convergence of the algorithm is shown under the condition that the estimation error of the linear mapping matrix from voltage to current is small. Simulation results are presented to illustrate the convergence of the output current.

摘要

相似文献

2
A high-precision voltage source for EIT.
Physiol Meas. 2006 May;27(5):S221-36. doi: 10.1088/0967-3334/27/5/S19. Epub 2006 Apr 24.
3
Lobe based image reconstruction in Electrical Impedance Tomography.
Med Phys. 2017 Feb;44(2):426-436. doi: 10.1002/mp.12038. Epub 2017 Jan 25.
5
A floating wide-band current source for electrical impedance tomography.
Rev Sci Instrum. 2018 Aug;89(8):085107. doi: 10.1063/1.5028435.
6
Frequency-difference electrical impedance tomography (fdEIT): algorithm development and feasibility study.
Physiol Meas. 2008 Aug;29(8):929-44. doi: 10.1088/0967-3334/29/8/006. Epub 2008 Jul 4.
7
Electrical impedance tomography. Electrode current determination from programmable voltage sources.
Clin Phys Physiol Meas. 1992;13 Suppl A:43-6. doi: 10.1088/0143-0815/13/a/009.
8
Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging.
Physiol Meas. 2008 Oct;29(10):R1-26. doi: 10.1088/0967-3334/29/10/R01. Epub 2008 Sep 17.
9
Improved resolution of D-bar images of ventilation using a Schur complement property and an anatomical atlas.
Med Phys. 2022 Jul;49(7):4653-4670. doi: 10.1002/mp.15669. Epub 2022 May 5.
10
Electrical impedance tomography of complex conductivity distributions with noncircular boundary.
IEEE Trans Biomed Eng. 1997 Nov;44(11):1051-60. doi: 10.1109/10.641332.

本文引用的文献

1
Distinguishability of conductivities by electric current computed tomography.
IEEE Trans Med Imaging. 1986;5(2):91-5. doi: 10.1109/TMI.1986.4307752.
3
Three-dimensional electrical impedance tomography.
Nature. 1996 Apr 11;380(6574):509-12. doi: 10.1038/380509a0.
4
An adaptive current tomography using voltage sources.
IEEE Trans Biomed Eng. 1993 Feb;40(2):163-8. doi: 10.1109/10.212056.
5
ACT3: a high-speed, high-precision electrical impedance tomograph.
IEEE Trans Biomed Eng. 1994 Aug;41(8):713-22. doi: 10.1109/10.310086.
6
A real-time electrical impedance tomography system for clinical use--design and preliminary results.
IEEE Trans Biomed Eng. 1995 Feb;42(2):133-40. doi: 10.1109/10.341825.
7
A real-time electrical impedance tomograph.
IEEE Trans Biomed Eng. 1995 Sep;42(9):849-59. doi: 10.1109/10.412652.
8
An electric current tomograph.
IEEE Trans Biomed Eng. 1988 Oct;35(10):828-33. doi: 10.1109/10.7289.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验