Stanton A C, Silver J A
Appl Opt. 1988 Dec 15;27(24):5009-15. doi: 10.1364/AO.27.005009.
Hydrogen chloride gas is measured by absorption in the second overtone band near 1.2microm using an InGaAsP diode laser. The strength and air-broadening coefficient of the H(35)Cl P(3) line are measured. The line strength is ~18% higher than the previous grating spectrometer measurement and suggests that the commonly used experimental value for the 3 ?0 HCl vibrational moment may be low. High-frequency two-tone FM detection is also used in this study to measure trace concentrations of HCl. Using a multimode laser, the sensitivity limit is 3-parts per million HCl in air at 50 Torr, corresponding to a minimum detectable fractional absorption (multimode) of 4 x 10(-6). Optimization of the detection method should permit real-time measurement of concentrations below 0.1 ppm. The low cost and convenient operating characteristics of InGaAsP diode lasers make them attractive for many applications in high-resolution near-IR spectroscopy and trace species detection.
使用铟镓砷磷二极管激光器,通过在1.2微米附近的二次泛音带中的吸收来测量氯化氢气体。测量了H(35)Cl P(3)线的强度和空气展宽系数。该线强度比先前的光栅光谱仪测量值高约18%,这表明常用的3?0 HCl振动力矩实验值可能偏低。本研究还使用高频双音调频检测来测量痕量浓度的HCl。使用多模激光器时,在50托的空气中,灵敏度极限为百万分之三的HCl,对应于最小可检测分数吸收(多模)为4×10(-6)。检测方法的优化应能实现低于0.1 ppm浓度的实时测量。铟镓砷磷二极管激光器的低成本和便捷操作特性使其在高分辨率近红外光谱和痕量物种检测的许多应用中具有吸引力。