Arkansas Specialty Orthopaedics, Little Rock, Arkansas, USA.
J Arthroplasty. 2011 Jun;26(4):549-54. doi: 10.1016/j.arth.2010.04.027. Epub 2010 Jun 11.
Nine ADVANCE (Wright Medical Technology, Arlington, TN)) Medial-Pivot (MP) and 9 ADVANCE Double-High total knee arthroplasties were analyzed under radiographic surveillance at standing, mid kneeling, and full kneeling. In vivo tibiofemoral contact positions were obtained using the 3- to 2-dimensional image registration technique. The contact in Double-High knee was always more posterior than that in the MP knee presumably because of the presence of the posterior cruciate ligament. The contact positions in both the designs moved anterior from standing to mid kneeling, moved posterior from mid kneeling to full kneeling, and remained within the intended articulation range of the implants. This study indicates that kneeling is safe in MP total knee arthroplasty even in the absence of a cam-post or posterior cruciate ligament.
9 例 ADVANCE(Wright Medical Technology,田纳西州阿灵顿)内侧铰链(MP)和 9 例 ADVANCE 双高全膝关节置换术后在站立位、半蹲位和全蹲位下进行放射学监测分析。使用 3-2 维图像配准技术获得膝关节置换术后胫骨股骨的接触位置。双高膝关节的接触位置始终比 MP 膝关节更靠后,这可能是因为存在后交叉韧带。两种设计的接触位置从站立位到半蹲位向前移动,从中蹲位到全蹲位向后移动,并且都在植入物的预期关节范围内。这项研究表明,即使没有凸轮-后柱或后交叉韧带,在 MP 全膝关节置换术后也可以安全地进行蹲姿。