Suppr超能文献

Rate of Recanalization and Safety of Endovascular Embolization of Intracranial Saccular Aneurysms Framed with GDC 360 Coils.

作者信息

Ortiz R, Song J, Niimi Y, Berenstein A

机构信息

Hyman-Newman Institute of Neurology and Neurosurgery, Center for Endovascular Surgery, New York, USA -

出版信息

Interv Neuroradiol. 2008 Dec 29;14(4):397-401. doi: 10.1177/159101990801400405. Epub 2009 Jan 5.

Abstract

Coil compaction and recanalization of cerebral aneurysms treated with coil embolization continue to be of great concern, especially in patients that presented with subarachnoid hemorrhage. The incidence of recanalization reported by previous studies ranges from 12 to 40 percent in experienced centers. We reviewed the incidence of recanalization requiring retreatment in patients treated with GDC 360 framing coils. A retrospective review of every patient who underwent coil embolization with GDC 360 coils for saccular aneurysms at our institution from December 2004 to March 2008 was performed. We studied the patients' demographics, clinical presentation, aneurysm size and configuration, type of coils used to embolize the aneurysm, the percentage of coils that were GDC 360 in any given aneurysm, the need for remodeling techniques like stent and/or balloon for embolization, immediate complications, cases in which we were unable to frame with the GDC 360 coil, and rate of recanalization on follow- up. A total of 110 patients (33 men, 77 women) and 114 aneurysms were treated with GDC 360 coils. Ninety-eight aneurysms were framed with the GDC 360 coils. There were two patients in whom the initial GDC 360 coil intended for framing had to be pulled out and exchanged for another type of coil. There were five procedure related complications (4.4%). Four patients required intra-arterial abciximab due to thrombus formation. One patient that presented with a grade III subarachnoid hemorrhage had aneurysm rupture while the coil was being advanced. A total of 50 patients (15 men and 35 women) underwent follow-up femoral cerebral angiograms at least six months after coiling (mean follow-up was 15 months). Forty-four of the patients with follow-up had the GDC 360 coil used as a framing coil. Three patients (6%) required retreatment due to recanalization. Every patient with recanalization requiring treatment had aneurysms of the anterior communicating complex that presented with subarachnoid hemorrhage. The rate of recanalization of cerebral aneurysms embolized with GDC 360 framing coils was lower in our case series compared to the existing literature reports. Patients with aneurysms of the anterior communicating artery were at increased incidence of recanalization in our patient cohort.

摘要

相似文献

1
Rate of Recanalization and Safety of Endovascular Embolization of Intracranial Saccular Aneurysms Framed with GDC 360 Coils.
Interv Neuroradiol. 2008 Dec 29;14(4):397-401. doi: 10.1177/159101990801400405. Epub 2009 Jan 5.
3
Coil embolization for intracranial aneurysms: an evidence-based analysis.
Ont Health Technol Assess Ser. 2006;6(1):1-114. Epub 2006 Jan 1.
4
Efficacy of a 14-coil for Framing in Coil Embolization of Small Cerebral Aneurysms.
J Neuroendovasc Ther. 2020;14(9):351-357. doi: 10.5797/jnet.oa.2020-0027. Epub 2020 Jun 10.
8
Initial clinical experience with matrix detachable coils for the treatment of intracranial aneurysms.
J Neurosurg. 2006 Aug;105(2):192-9. doi: 10.3171/jns.2006.105.2.192.

引用本文的文献

1
Experimental Study of Coil Compaction: Impact of Pulsatile Stress.
J Neuroendovasc Ther. 2022;16(1):12-18. doi: 10.5797/jnet.oa.2021-0023. Epub 2021 May 7.
4
Flow diversion versus traditional endovascular coiling therapy: design of the prospective LARGE aneurysm randomized trial.
AJNR Am J Neuroradiol. 2014 Jul;35(7):1341-5. doi: 10.3174/ajnr.A3968. Epub 2014 May 15.

本文引用的文献

1
Initial experience with bioactive cerecyte detachable coils: impact on reducing recurrence rates.
Neurosurgery. 2008 Apr;62(4):799-805; discussion 805-6. doi: 10.1227/01.neu.0000318163.44601.c7.
2
Cigarette smoking as a risk factor for recurrence of aneurysms treated by endosaccular occlusion.
J Neurosurg. 2008 Apr;108(4):672-5. doi: 10.3171/JNS/2008/108/4/0672.
3
Safety of endovascular treatment of intracranial aneurysms with a new, complex shaped Guglielmi detachable coil.
Neuroradiology. 2007 Sep;49(9):761-6. doi: 10.1007/s00234-007-0247-8. Epub 2007 Jun 14.
8
Repeat endovascular treatment in post-embolization recurrent intracranial aneurysms.
Neurosurgery. 2006 Jan;58(1):60-70; discussion 60-70. doi: 10.1227/01.neu.0000194188.51731.13.
10
Hydrogel-coated coils for the treatment of cerebral aneurysms: preliminary results.
Neurosurg Focus. 2005 Feb 15;18(2):E1. doi: 10.3171/foc.2005.18.2.2.