Suppr超能文献

经阴道超声检查、生理盐水灌注子宫声学造影与宫腔镜检查在绝经后出血中的诊断准确性比较。

Comparison of diagnostic accuracy of saline infusion sonohysterography, transvaginal sonography and hysteroscopy in postmenopausal bleeding.

机构信息

IVF Center, Gayrettepe Florence Nightingale Hospital, Istanbul Bilim University, Istanbul, Turkey.

出版信息

Arch Gynecol Obstet. 2011 Jul;284(1):111-7. doi: 10.1007/s00404-010-1604-0. Epub 2010 Jul 28.

Abstract

OBJECTIVE

To compare the diagnostic accuracy of transvaginal sonography (TVS), saline infusion sonohysterography (SIS) and hysteroscopy (HS) with respect to pathological diagnosis in the detection of uterine cavity abnormalities associated with abnormal uterine bleeding among postmenopausal women.

METHODS

Being a prospective, investigator-blind trial, the present study was conducted on 137 postmenopausal women, with abnormal uterine bleeding, admitted to the Department of Obstetrics and Gynecology of Istanbul Bilim University, Florence Nightingale Hospital and Fertigyn Woman Health and IVF Center. After TVS, all patients underwent SIS using Cook Soft 500 IVF transfer catheter and HS, consecutively. Sensitivity, specificity, and positive and negative predictive values (PPV and NPV) were calculated to compare the diagnostic accuracy of TVS, SIS and HS.

RESULTS

Most commonly encountered endometrial lesions were polypoid lesion (38.0%) and hyperplasia (28.4%) among our study population consisting of 137 women (mean age 61.6 ± 9.6 years) in their postmenopausal stage. Overall sensitivity rates were 70.0% for TVS, 89.6% for SIS and 92.3% for HS, while the overall specificity rates were 50.0, 77.3 and 80.7%, respectively. HS had PPV of 96.2% and NPV of 65.3%, whereas PPV was determined to be 80.9 versus 95.3% and NPV was 35.4 versus 58.3% for TVS and SIS, respectively.

CONCLUSIONS

As an easy to perform, safe and well-tolerated procedure yielding high diagnostic accuracy, saline infusion SIS via this catheter seems to be superior to TVS and very close to HS. It may be used as the primary method for the detection of uterine abnormalities among postmenopausal women with abnormal uterine bleeding.

摘要

目的

比较经阴道超声(TVS)、盐水灌注超声造影(SIS)和宫腔镜(HS)在检测绝经后妇女异常子宫出血相关宫腔异常方面的诊断准确性,并与病理诊断进行比较。

方法

本研究为前瞻性、研究者盲法试验,纳入了 137 名因异常子宫出血就诊于伊斯坦布尔 Bilim 大学、佛罗伦萨南丁格尔医院妇产科和 Fertigyn 女性健康和 IVF 中心的绝经后妇女。所有患者在 TVS 后均使用 Cook Soft 500 IVF 转移导管进行 SIS,然后进行 HS。计算敏感性、特异性、阳性和阴性预测值(PPV 和 NPV),以比较 TVS、SIS 和 HS 的诊断准确性。

结果

在我们的研究人群中,最常见的子宫内膜病变是息肉样病变(38.0%)和增生(28.4%),该人群由 137 名绝经后妇女(平均年龄 61.6 ± 9.6 岁)组成。TVS 的总体敏感性率为 70.0%,SIS 为 89.6%,HS 为 92.3%,而 TVS 的总体特异性率为 50.0%,SIS 为 77.3%,HS 为 80.7%。HS 的 PPV 为 96.2%,NPV 为 65.3%,而 TVS 和 SIS 的 PPV 分别为 80.9%和 95.3%,NPV 分别为 35.4%和 58.3%。

结论

作为一种易于操作、安全且耐受性良好的方法,具有较高的诊断准确性,通过该导管进行盐水灌注 SIS 似乎优于 TVS,与 HS 非常接近。它可以作为绝经后异常子宫出血妇女检测宫腔异常的首选方法。