Suppr超能文献

使用纤维蛋白密封剂进行蛛网膜成形术后的过敏反应。

Allergic reaction following arachnoid plasty with a fibrin sealant.

作者信息

Kanazawa Ryuzaburo, Sato Shun, Iwamoto Naotaka, Teramoto Akira

机构信息

Department of Neurosurgery, Nagareyama Central Hospital, Nagareyama, Chiba, Japan.

出版信息

Neurol Med Chir (Tokyo). 2010;50(7):608-10. doi: 10.2176/nmc.50.608.

Abstract

A 65-year-old woman underwent surgical treatment of an unruptured aneurysm in the left middle cerebral artery. Surgical craniotomy using arachnoid plasty with a fibrin sealant was completed without incident, but abrupt neurological deterioration occurred on the 9th postoperative day. Antibiotic treatment was given, but the symptoms did not resolve. Neuroimaging and physical findings indicated allergic reaction rather than infectious process. Therefore, systemic steroids were administered that resulted in dramatic resolution of symptoms. Nine months later, lymphocyte stimulation test of materials used in arachnoid plasty revealed positive response to a component of the combination pair in fibrin glue. The fibrin sealant placement method is a widely accepted and familiar technique, but surgeons should anticipate possible allergic reactions such as those observed in the present case.

摘要

一名65岁女性接受了左侧大脑中动脉未破裂动脉瘤的手术治疗。采用蛛网膜成形术加纤维蛋白密封剂进行手术开颅,手术顺利完成,但术后第9天突然出现神经功能恶化。给予抗生素治疗,但症状未缓解。神经影像学和体格检查结果表明是过敏反应而非感染过程。因此,给予全身类固醇治疗,症状得到显著缓解。9个月后,对蛛网膜成形术中使用的材料进行淋巴细胞刺激试验,结果显示对纤维蛋白胶组合对中的一种成分呈阳性反应。纤维蛋白密封剂放置方法是一种广泛接受且熟悉的技术,但外科医生应预料到可能出现的过敏反应,如本病例中观察到的情况。