Miyauchi Toshiyuki, Miyachi Yasutaka, Takahashi Makoto, Ishikawa Norihisa, Mori Hidehiko
Department of Applied Chemistry, College of Engineering, Chubu University, Kasugai, Aichi 487-8501, Japan.
Anal Sci. 2010;26(8):847-51. doi: 10.2116/analsci.26.847.
A quantitative method for the determination of urea in serum was studied. An ion chromatograph (IC) with a conductivity detector was used in this method, where the chromatograph was modified by placing an immobilized urease column between the injection loop and a guard column of the cation analysis column. Immobilized urease was prepared by the adsorption of urease on cedar sawdust with triethylenetetramine. The adsorption capacity of urease was 190 mg g(-1), and its activity was 3500 U g(-1). The conversion efficiency of urea to ammonium ion was 100%, and the half life of immobilized urease was 60 days. It was possible to use the immobilized urease in a pH range of 3.0 to 9.0, and at temperatures up to 60 degrees C. The determination of urea was attempted by IC attaching an immobilized urease column. The limit of detection of urea was 0.2 mg L(-1), and the calibration curves of urea were very linear over 0.8-25 mg L(-1). The urea concentration in the human serum could be determined with a standard deviation of 0.06-0.13 within 5 min after injecting the serum sample.
研究了一种测定血清中尿素的定量方法。该方法采用配有电导检测器的离子色谱仪(IC),通过在进样环和阳离子分析柱的保护柱之间放置固定化脲酶柱对色谱仪进行了改进。固定化脲酶通过用三亚乙基四胺将脲酶吸附在雪松锯末上制备而成。脲酶的吸附容量为190 mg g(-1),其活性为3500 U g(-1)。尿素向铵离子的转化效率为100%,固定化脲酶的半衰期为60天。固定化脲酶可在pH值3.0至9.0的范围内以及高达60℃的温度下使用。尝试通过连接固定化脲酶柱的离子色谱法测定尿素。尿素的检测限为0.2 mg L(-1),尿素的校准曲线在0.8 - 25 mg L(-1)范围内呈非常好的线性关系。在注入血清样品后5分钟内,可测定人血清中的尿素浓度,标准偏差为0.06 - 0.13。