Suppr超能文献

评估人体阻抗,以满足高达 110MHz 频率的接触电流的安全要求。

Assessment of human body impedance for safety requirements against contact currents for frequencies up to 110 MHz.

机构信息

University of L'Aquila, L'Aquila, Italy.

出版信息

IEEE Trans Biomed Eng. 2011 Feb;58(2):390-6. doi: 10.1109/TBME.2010.2066273. Epub 2010 Aug 12.

Abstract

This paper deals with contact currents that may occur when the human body is in contact with two electrodes at different electrical potentials, e.g., an electrical/electronic device and the floor. Actually, any device must comply not only with electromagnetic compatibility and safety requirements, but also with specific electromagnetic field exposure recommendations in order to prevent health hazards for the occupational and general public population. Since the contact currents depend on the applied voltage and on the human body impedance, this last parameter has been measured for several configurations in a broadband frequency range, from 40 Hz to 110 MHz. From the measurement results, a new equivalent circuit of the human body impedance is derived by using a vector-fitting procedure. This equivalent circuit is very easy and can be adopted for compliance tests against contact currents.

摘要

本文讨论了人体同时接触两个不同电位电极(例如,电子/电气设备和地面)时可能产生的接触电流。实际上,任何设备不仅必须符合电磁兼容性和安全要求,还必须符合特定电磁场暴露建议,以防止职业和一般公众的健康危害。由于接触电流取决于所施加的电压和人体阻抗,因此已在从 40 Hz 到 110 MHz 的宽带频率范围内针对几种配置测量了人体阻抗。根据测量结果,使用矢量拟合程序推导出人体阻抗的新等效电路。该等效电路非常简单,可用于接触电流的合规性测试。

相似文献

1
Assessment of human body impedance for safety requirements against contact currents for frequencies up to 110 MHz.
IEEE Trans Biomed Eng. 2011 Feb;58(2):390-6. doi: 10.1109/TBME.2010.2066273. Epub 2010 Aug 12.
3
Pilot measurements of ELF contact currents in some electric utility occupations.
J Occup Environ Hyg. 2006 Jun;3(6):323-33. doi: 10.1080/15459620600697642.
4
A portable meter for measuring low frequency currents in the human body.
Bioelectromagnetics. 2004 Jul;25(5):369-73. doi: 10.1002/bem.20000.
5
Body composition modeling in the calf using an equivalent circuit model of multi-frequency bioimpedance analysis.
Physiol Meas. 2005 Apr;26(2):S133-43. doi: 10.1088/0967-3334/26/2/013. Epub 2005 Mar 29.
6
A new method for electric impedance imaging using an eddy current with a tetrapolar circuit.
IEEE Trans Biomed Eng. 2009 Feb;56(2):400-6. doi: 10.1109/TBME.2008.2008169. Epub 2008 Oct 31.
7
A broadband high-frequency electrical impedance tomography system for breast imaging.
IEEE Trans Biomed Eng. 2008 Feb;55(2 Pt 1):650-9. doi: 10.1109/TBME.2007.903516.
8
Modeling the frequency dependence of the electrical properties of the live human skull.
Physiol Meas. 2009 Dec;30(12):1293-301. doi: 10.1088/0967-3334/30/12/001. Epub 2009 Oct 20.
9
Statistical estimation of resistance/conductance by electrical impedance tomography measurements.
IEEE Trans Med Imaging. 2004 Jul;23(7):829-38. doi: 10.1109/TMI.2004.827965.

引用本文的文献

2
Computational models for contact current dosimetry at frequencies below 1 MHz.
Med Biol Eng Comput. 2021 Jan;59(1):107-119. doi: 10.1007/s11517-020-02284-9. Epub 2020 Dec 2.