Effect of gingival ceramic veneer thickness on the fracture strength of zirconia-based fixed dental prostheses.

作者信息

Gabbert Olaf, Ohlmann Brigitte, Schmitter Marc, Farhan Daniel, Becker Falk, Rammelsberg Peter

机构信息

Department of Prosthodontics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.

出版信息

Am J Dent. 2010 Jun;23(3):147-51.

Abstract

PURPOSE

To assess the effect of different thicknesses of porcelain at the gingival of pontics, on the fracture load of zirconia-based, all-ceramic fixed dental prostheses (FDPs), anchored by inlays.

METHODS

Box inlay cavities were prepared on mandibular molars and premolars. 40 FDPs with yttrium-stabilized zirconia frameworks of identical dimensions were manufactured using a CAD/CAM system and veneered with a press ceramic. The FDPs, replacing a premolar and a molar, were divided into four groups. In Group FR, the framework was all around unveneered. The next three groups received a 1 mm ceramic veneer on the buccal, occlusal and lingual side, but differed in the thickness of the ceramic veneer in the gingival, tensile zone of the pontics. In Group B-0, the gingival veneering was 0 mm, in Group B 1 mm and in Group B-2, 2 mm of gingival porcelain. A group of inlay-retained metal-ceramic FDPs (mc) served as control. All FDPs were subjected to thermal cycling and 600,000 cycles of mechanical load of 50 N. The load to fracture (N) was measured and fracture sites were evaluated macroscopically. A single-factor Analysis of Variance was used to analyze the data.

RESULTS

None of the FDPs debonded after thermal cycling or mechanical loading and no signs of fractures or other defects were observed. The mean fracture loads and standard deviations in parentheses were: 647 N (123) for Group B-0, 716 N (102) for Group FR, 812 N (48) for Group B-1, 934 N (129) for Group B-2 and 1005 N (SD 81) for Group MC. Means for Groups B-0 and FR were not shown to differ, and the same for mean fracture strength of Groups B-2 and MC.

摘要

目的

评估桥体龈端不同厚度的瓷层对嵌体固位的氧化锆基全瓷固定义齿(FDPs)断裂载荷的影响。

方法

在下颌磨牙和前磨牙上制备盒形嵌体洞型。使用计算机辅助设计/计算机辅助制造(CAD/CAM)系统制作40个尺寸相同的钇稳定氧化锆框架的FDPs,并采用压铸陶瓷进行 veneered。替换一颗前磨牙和一颗磨牙的FDPs分为四组。在FR组中,框架四周未进行 veneered。接下来的三组在颊侧、咬合面和舌侧有1mm的瓷层,但桥体龈端拉伸区的瓷层厚度不同。在B-0组中,龈端 veneering为0mm,B组为1mm,B-2组为2mm龈端瓷。一组嵌体固位的金属陶瓷FDPs(mc)作为对照。所有FDPs均进行热循环和50N的600,000次机械加载。测量断裂载荷(N)并宏观评估断裂部位。采用单因素方差分析对数据进行分析。

结果

热循环或机械加载后,所有FDPs均未脱粘,未观察到骨折或其他缺陷的迹象。括号内的平均断裂载荷和标准差分别为:B-0组647N(123),FR组716N(102),B-组812N(48),B-2组934N(129),MC组1005N(标准差81)。未显示B-0组和FR组的均值有差异。B-2组和MC组的平均断裂强度也相同。