Institute of Clinical Medicine, Aarhus University Hospital Skejby, Aarhus N, Denmark.
J Pediatr Urol. 2011 Aug;7(4):404-11. doi: 10.1016/j.jpurol.2010.07.011. Epub 2010 Aug 17.
To investigate the biomechanical, histological and biochemical properties of rabbit urethra at long-term follow up after hypospadias simulation and acute repair.
Thirty-eight white New Zealand male rabbits underwent experimental creation of a hypospadias-like defect and acute repair (mobilization and advancement, tubularized incised posterior urethral plate (TIP), modified TIP) and sham operation. After 23 weeks all groups + controls underwent biomechanical, histological and biochemical assessments.
The mobilization and advancement group showed a higher stiffness compared to the TIP groups (P < 0.05) in the posterior urethra, whereas the TIP group was stiffer compared to the other two operative groups (P < 0.001) in the ventral urethra. In the dorsal urethra, the mobilization and advancement group and the modified TIP group had a higher collagen content compared to shams (P < 0.05). No differences in collagen content were found between groups in the ventral urethra. A correlation between acoustic and histological layers was found, partially related to collagen content.
The urethras had different microelastic properties in different layers of the dorsal and ventral urethra, with higher stiffness in the connective tissue layers surrounding and within the urethra. The repaired urethras had partially recovered their elasticity at micrometer resolution at long-term follow up. Scanning acoustic microscopy elucidated structure-function relationships at microscopic level in normal and operated urethra.
研究在长期随访后模仿尿道下裂并进行急性修复后,兔尿道的生物力学、组织学和生物化学特性。
38 只新西兰雄性白兔进行了尿道下裂样缺损的实验性创建和急性修复(动员和推进,管状切开后的尿道板(TIP),改良 TIP)和假手术。23 周后,所有组+对照组均进行了生物力学、组织学和生物化学评估。
在尿道后段,动员和推进组的硬度高于 TIP 组(P <0.05),而在尿道前段,TIP 组的硬度高于其他两个手术组(P <0.001)。在尿道背段,动员和推进组和改良 TIP 组的胶原含量高于假手术组(P <0.05)。在尿道前段,各组之间的胶原含量无差异。声学和组织学层之间存在相关性,部分与胶原含量有关。
尿道在背段和前段的不同层具有不同的微观弹性特性,尿道周围和内部的结缔组织层具有较高的刚度。在长期随访中,修复后的尿道在微米分辨率下部分恢复了弹性。扫描声学显微镜在微观水平上阐明了正常和手术尿道的结构-功能关系。