Abstract

During the past two decades, important progress has been achieved in the treatment of end-stage congestive heart failure in newborns and infants. The use of ventricular assist devices (VAD) in these patients is now available as a bridge to heart transplantation. The use of a VAD may reveal the presence of a silent interatrial septal defect or a patent foramen ovale (PFO), inducing a right to left shunt resulting in systemic desaturation and hemodynamic instability. We present two cases of low weight infants on circulatory support with VADs and right to left shunt through interatrial septum that were successfully treated by percutaneous intervention with an occlusion device.

摘要

在过去的二十年中,新生儿和婴儿充血性心力衰竭的治疗取得了重要进展。心室辅助装置(VAD)的使用现在可作为心脏移植的桥梁。VAD 的使用可能会揭示存在无症状房间隔缺损或卵圆孔未闭(PFO),导致右向左分流,从而导致全身饱和度降低和血流动力学不稳定。我们介绍了两例在循环支持下使用 VAD 并通过房间隔出现右向左分流的低体重婴儿,通过经皮介入使用封堵装置成功治疗。