Suppr超能文献

稳定型转子间骨折软组织血清标志物比较:动力髋螺钉与股骨近端髓内钉——初步研究。

Comparison of soft-tissue serum markers in stable intertrochanteric fracture: dynamic hip screw versus proximal femoral nail—A preliminary study.

机构信息

Department of Orthopedic Surgery, Korea University Ansan Hospital, Seoul, Republic of Korea.

出版信息

Injury. 2011 Feb;42(2):204-8. doi: 10.1016/j.injury.2010.09.008.

Abstract

DESIGN

Prospective randomised comparative study.

OBJECTIVES

To analyse and compare serum soft-tissue marker differences after dynamic hip screw (DHS)and proximal femoral nail (PFN) fixation of stable intertrochanteric fractures in the elderly.

MATERIALS AND METHODS

Twenty elderly patients (>60 years old) with a stable intertrochanteric fracture were enrolled in this study. Patients were divided into two groups of 10 each according to the device used (DHS or PFN). All 20 patients had a stable intertrochanteric fracture, and all were operated on by the same surgeon using minimal invasive approach. A biochemical comparison of soft-tissue serum markers was performed. The serum markers examined were haemoglobin (Hb), haematocrit (Hct), creatine kinase (CK), myoglobin (MYO), troponin I and C-reactive protein (CRP), and their levels were determined before surgery, and 1, 8, 16, 24, 36, 48 and 72 h after surgery. Differences between the DHS and PFN groups were compared.

RESULTS

No inter-group differences were observed with respect to preoperative demographics,operation time, incision length or blood loss. In terms of serum markers, both methods showed similar patterns of change for CK, MYO and CRP pre- to post-operatively. In addition, pre- and postoperative Hb and Hct levels were similar. Furthermore, no inter-group differences were observed between the absolute values of serum markers at any point.

CONCLUSION

The absolute values and temporal changes of serum markers were similar in the two study groups. These findings suggest that DHS and PFN fixation of stable intertrochanteric fractures produce similar levels of soft-tissue damage.

摘要

设计

前瞻性随机对照研究。

目的

分析和比较动力髋螺钉(DHS)和股骨近端髓内钉(PFN)固定老年稳定型股骨转子间骨折后血清软组织标志物的差异。

材料与方法

本研究纳入 20 例老年(>60 岁)稳定型股骨转子间骨折患者。根据使用的器械(DHS 或 PFN)将患者分为两组,每组 10 例。所有 20 例患者均为稳定型股骨转子间骨折,均由同一位外科医生采用微创入路进行手术。对软组织血清标志物进行生化比较。检测的血清标志物包括血红蛋白(Hb)、血细胞比容(Hct)、肌酸激酶(CK)、肌红蛋白(MYO)、肌钙蛋白 I 和 C 反应蛋白(CRP),并在术前以及术后 1、8、16、24、36、48 和 72 h 测定其水平。比较 DHS 和 PFN 两组之间的差异。

结果

两组患者术前人口统计学、手术时间、切口长度或出血量无组间差异。就血清标志物而言,两种方法的 CK、MYO 和 CRP 术前至术后的变化模式均相似。此外,Hb 和 Hct 水平的术前和术后值相似。此外,在任何时间点,两组之间的血清标志物绝对值均无差异。

结论

两组研究中,血清标志物的绝对值和时间变化相似。这些发现表明 DHS 和 PFN 固定稳定型股骨转子间骨折产生相似水平的软组织损伤。