Trojanowski T
Neurol Neurochir Pol. 1978 May-Jun;12(3):309-13.
The results of cerebral angiography and isotope scintigraphy were compared in 50 patients with brain tumours. The usefulness of each method for detection, localization and determination of the size of the tumour was evaluated. The overall detection rate of brain tumours was 92% in the case of angiography and 90% for scintigraphy, the possiblity of localization was 86% and 90% and size determination was 50% and 74% respectively. Scintigraphy often failed in the diagnosis of astrocytomas and tumours situated near the base of the brain, but this method was more reliable in evaluating the site and size of tumours than angiography.
对50例脑肿瘤患者的脑血管造影和同位素闪烁扫描结果进行了比较。评估了每种方法在肿瘤检测、定位和大小测定方面的实用性。脑血管造影对脑肿瘤的总体检测率为92%,闪烁扫描为90%;定位可能性分别为86%和90%;大小测定可能性分别为50%和74%。闪烁扫描在星形细胞瘤和位于脑底部附近肿瘤的诊断中常出现失败,但该方法在评估肿瘤部位和大小方面比脑血管造影更可靠。