Suppr超能文献

光纤布拉格光栅低温温度传感器。

Fiber Bragg grating cryogenic temperature sensors.

作者信息

Gupta S, Mizunami T, Yamao T, Shimomura T

出版信息

Appl Opt. 1996 Sep 1;35(25):5202-5. doi: 10.1364/AO.35.005202.

Abstract

Temperature sensing to as low as 80 K was demonstrated with 1.55-μm fiber Bragg gratings. The gratings were bonded on substrates to increase sensitivity, and a shift of the reflection wavelength was measured. The temperature sensitivity was 0.02 nm/K at 100 K when an aluminum substrate was used and 0.04 nm/K at 100 K when a poly(methyl methacrylate) substrate was used. These values are smaller than those at room temperature because of the nonlinearity of both the thermal expansion and the thermo-optic effect. Extension to the liquid helium temperature is also discussed.

摘要

利用1.55微米的光纤布拉格光栅实现了低至80K的温度传感。这些光栅被粘贴在基板上以提高灵敏度,并测量了反射波长的偏移。当使用铝基板时,在100K下的温度灵敏度为0.02nm/K,当使用聚甲基丙烯酸甲酯基板时,在100K下的温度灵敏度为0.04nm/K。由于热膨胀和热光效应的非线性,这些值比室温下的值小。还讨论了向液氦温度的扩展。