确定髋关节中心的位置:将蚌线形状应用于磁共振图像的髋臼软骨表面。

Determining the location of hip joint centre: application of a conchoid's shape to the acetabular cartilage surface of magnetic resonance images.

作者信息

Kang M J, Sadri H, Stern R, Magnenat-Thalmann N, Hoffmeyer P, Ji H S

机构信息

KIBO Technology Fund, Samsung, Seoul, South Korea.

出版信息

Comput Methods Biomech Biomed Engin. 2011;14(1):65-71. doi: 10.1080/10255842.2010.495064. Epub 2010 Nov 1.

Abstract

Preoperative planning, or intraoperative navigation of hip surgery, including joint-preserving procedures such as osteotomy or joint-replacing procedures such as total arthroplasty, needs to be performed with a high degree of accuracy to ensure a successful outcome. The ability to precisely localise the hip joint rotation centre may prove to be very useful in this context. The human hip joint has been shown to be a conchoid shape, and therefore the accurate location of the hip joint centre (HJC) cannot be computed simply as the centre of a sphere. This study describes a method for determining the HJC by applying a conchoid shape to the acetabular cartilage surface of magnetic resonance images, in order to increase the accuracy of the HJC location which had previously been calculated by a functional method using reconstructed three-dimensional surface bony models. By approximating a conchoid shape to the acetabulum, it was possible to compensate for HJC calculation errors.

摘要

髋关节手术的术前规划或术中导航,包括诸如截骨术等保关节手术或诸如全关节置换术等关节置换手术,都需要高精度地进行,以确保手术成功。在这种情况下,精确确定髋关节旋转中心的能力可能会非常有用。研究表明,人体髋关节呈蚌线形状,因此不能简单地将髋关节中心(HJC)计算为球体的中心。本研究描述了一种通过将蚌线形状应用于磁共振图像的髋臼软骨表面来确定HJC的方法,以提高先前使用重建的三维表面骨模型通过功能方法计算的HJC定位的准确性。通过使髋臼近似蚌线形状,可以补偿HJC计算误差。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验