Consistency is one of the most important concerns to convey stable artificially induced sensory feedback. However, the constancy of perceived sensations cannot be guaranteed, as the artificially evoked sensation is a function of the interaction of stimulation parameters. The hypothesis of this study is that the selected stimulation parameters in multi-electrode cutaneous stimulation have significant impacts on the perception threshold.
The investigated parameters included the stimulated location, the number of active electrodes, the number of pulses, and the interleaved time between a pair of electrodes. Biphasic, rectangular pulses were applied via five surface electrodes placed on the forearm of 12 healthy subjects.
Our main findings were: 1) the perception thresholds at the five stimulated locations were significantly different (p < 0.0001), 2) dual-channel simultaneous stimulation lowered the perception thresholds and led to smaller variance in perception thresholds compared to single-channel stimulation, 3) the perception threshold was inversely related to the number of pulses, and 4) the perception threshold increased with increasing interleaved time when the interleaved time between two electrodes was below 500 μs.
To maintain a consistent perception threshold, our findings indicate that dual-channel simultaneous stimulation with at least five pulses should be used, and that the interleaved time between two electrodes should be longer than 500 μs. We believe that these findings have implications for design of reliable sensory feedback codes.
一致性是传递稳定的人工诱发感觉反馈的最重要关注点之一。然而,由于人为诱发的感觉是刺激参数相互作用的函数,因此不能保证感觉的恒定性。本研究的假设是,多电极皮肤刺激中选择的刺激参数对感知阈值有显著影响。
研究的参数包括刺激位置、活动电极的数量、脉冲数量以及一对电极之间的交错时间。通过放置在前臂上的五个表面电极施加双相、矩形脉冲,共 12 名健康受试者参与了研究。
我们的主要发现是:1)五个刺激位置的感知阈值有显著差异(p<0.0001);2)双通道同时刺激降低了感知阈值,并导致感知阈值的方差小于单通道刺激;3)感知阈值与脉冲数量呈反比关系;4)当两个电极之间的交错时间超过 500μs 时,交错时间增加会导致感知阈值增加。
为了保持一致的感知阈值,我们的研究结果表明,应使用至少五个脉冲的双通道同时刺激,并且两个电极之间的交错时间应大于 500μs。我们相信这些发现对可靠感觉反馈码的设计具有启示意义。