Suppr超能文献

仅使用光子与光子/电子混合治疗计划进行部分乳腺照射的患者的临床和剂量学结果比较。

A comparison of clinical and dosimetric outcomes in patients receiving partial breast irradiation with photon-only versus mixed photon/electron treatment plans.

作者信息

Shah Mira M, Horton Janet K, Yoo Sua, Hubbs Jessica L, Demirci Senem, Light Kim L, Temple Kathy, Patrone Michael, Marks Lawrence B

机构信息

Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710, USA.

出版信息

Med Dosim. 2011 Winter;36(4):423-8. doi: 10.1016/j.meddos.2010.10.004. Epub 2011 Mar 26.

Abstract

Several series evaluating external-beam partial breast irradiation (PBI) have linked negative cosmetic outcomes to large normal tissue treatment volumes. We compared patients treated with PBI whose treatment plans included only photons to those whose plans incorporated electrons. Twenty-seven patients were identified: median age 67 years, pT1 82%, pN0 56%, margin negative 100%. All received 38.5 Gy using 3-5 noncoplanar photon beams (6-15X). Electrons (9-20 MeV) were included in 59%. Median follow-up was 22 months. Ninety percent experienced good/excellent cosmetic outcomes. Two patients had fair cosmesis, and both were treated with a mixed photon/electron approach. Median conformity index for photon-only treatment plans was 1.7 (range, 0.9-2.0) and for photon/electron plans, 1.0 (0.3-1.4). Median percent ipsilateral breast volume receiving 100% and 50% of prescription dose was 19 and 50 for photon-only plans vs. 10 and 38 for photon/electron plans (p < 0.05). Median percent target volume receiving 100% and 95% of prescription dose was 93 and 98 for photon-only plans vs. 75 and 94 for photon/electron plans (p < 0.05). A mixed photon/electron, noncoplanar technique decreases the volume of treated normal breast tissue at the cost of slightly decreased tumor bed coverage. Further study is needed to determine whether this results in a more favorable therapeutic ratio than photon-only approaches.

摘要

几个评估外照射部分乳腺放疗(PBI)的系列研究已将不良美容效果与较大的正常组织治疗体积联系起来。我们比较了接受PBI治疗的患者,其治疗计划仅包括光子的患者与计划纳入电子的患者。共确定了27例患者:中位年龄67岁,pT1为82%,pN0为56%,切缘阴性为100%。所有患者使用3 - 5个非共面光子束(6 - 15X)接受38.5 Gy的照射。59%的患者治疗计划中纳入了电子(9 - 20 MeV)。中位随访时间为22个月。90%的患者获得了良好/优秀的美容效果。2例患者美容效果一般,且均采用光子/电子混合方法治疗。仅光子治疗计划的中位适形指数为1.7(范围0.9 - 2.0),光子/电子计划为1.0(0.3 - 1.4)。仅光子计划中接受100%和50%处方剂量的同侧乳腺体积中位数分别为19和50,而光子/电子计划分别为10和38(p < 0.05)。仅光子计划中接受100%和95%处方剂量的靶体积中位数分别为93和98,光子/电子计划分别为75和94(p < 0.05)。光子/电子混合非共面技术以略微降低瘤床覆盖为代价,减少了正常乳腺组织的治疗体积。需要进一步研究以确定这是否会产生比仅使用光子方法更有利的治疗比。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验