Central Laboratory Animal Facility, Hannover Medical School, Hannover, Germany.
Vet J. 2012 Mar;191(3):354-9. doi: 10.1016/j.tvjl.2011.02.023. Epub 2011 Mar 30.
In order to provide objective measures of anaesthetic depth for periods without clinical signs (e.g., cardiopulmonary bypass [CPB]), the correlation between the electroencephalographic Narcotrend index (NI), 95% spectral edge frequency (SEF95), median power frequency (MPF) and clinical stages of anaesthesia was investigated in 16 juvenile sheep. Data were recorded during recovery from anaesthesia for pulmonary or aortic valve replacement. A significant (P<0.05) negative correlation was found between clinical stages of anaesthesia and NI (r(s) = -0.534) and SEF95 (r(s) = -0.543). No significant correlation existed between anaesthetic stages and MPF (r(s) = -0.292, P>0.05). The sensitivity of NI, SEF95 and MPF to assure an adequate level of anaesthesia was 71.43%, 66.67% and 44.44%, respectively, while the specificity of the descriptors ranged between 97.44 and 92.31%. No significant age-related effect on EEG data and stages of anaesthesia was detected when data from sheep between 4 and 6 months of age were compared with data obtained from 8- to 12-month old sheep. In conclusion, NI seems to be the most appropriate EEG descriptor to assure adequate depth of anaesthesia in juvenile, isoflurane-anaesthetized sheep.
为了提供无临床体征(例如心肺旁路[CPB])期间麻醉深度的客观测量,研究了 16 只幼年绵羊麻醉期间脑电图 Narcotrend 指数(NI)、95%谱边缘频率(SEF95)、中值功率频率(MPF)与麻醉临床阶段的相关性。数据记录于肺或主动脉瓣置换术后麻醉恢复期。麻醉临床阶段与 NI(r(s)=-0.534)和 SEF95(r(s)=-0.543)呈显著负相关(P<0.05)。麻醉阶段与 MPF 之间无显著相关性(r(s)=-0.292,P>0.05)。NI、SEF95 和 MPF 确保足够麻醉水平的灵敏度分别为 71.43%、66.67%和 44.44%,而描述符的特异性范围在 97.44%至 92.31%之间。当比较 4 至 6 月龄绵羊的数据与 8 至 12 月龄绵羊获得的数据时,未发现 EEG 数据和麻醉阶段与年龄相关的显著影响。总之,NI 似乎是确保幼年异氟醚麻醉绵羊麻醉深度足够的最合适 EEG 描述符。