Suppr超能文献

下肢功能部分负重测量的可靠性和有效性

Reliability and validity of a partial weight bearing measure of lower extremity performance.

作者信息

Cipriani Daniel J, Haines Michelle, O'Rand Denise, Levy Susan

机构信息

San Diego State University, San Diego, CA.

出版信息

N Am J Sports Phys Ther. 2009 May;4(2):49-59.

Abstract

BACKGROUND

Methods of measuring lower extremity function is limited for those with partial weight bearing (PWB) status in early phases of a lower extremity rehabilitation program.

OBJECTIVES

The purpose of this study was to measure intra-rater reliability of two lower extremity PWB performance measures using an incline exercise apparatus and to evaluate the concurrent validity and responsiveness to change of these two measures.

METHODS

Thirty-seven adult patients with lower extremity injuries were measured on two PWB measures (PWB20 and PWB30) of lower extremity performance as well as several common measures of LE function. After initial testing, subjects were asked to return for retesting, following four to six weeks of rehabilitation intervention. Reliability of the data from the measures was tested using intraclass correlation coefficients (ICC); validity was based on bivariate correlations of the measures. The minimal detectable change (MDC) value and limb symmetry index (LSI) were used to study the responsiveness of the PWB measures.

RESULTS

The ICC for the PWB20 and PWB30 were 0.95 and 0.98, respectively. The bivariate correlations of the PWB20 with stair climbing and walking speed were greater than those of the PWB30. Correlations ranged from r = 0.49 to 0.72 between the PWB measures and the functional measures. For most patients, their change in score between initial testing and follow-up exceeded the MDC; the LSI improved for all patients.

CONCLUSION

Using the incline apparatus yielded reliable PWB data. In addition, performance on the PWB measures correlated fairly well with common measures of function.

摘要

背景

在下肢康复计划的早期阶段,对于部分负重(PWB)状态的患者,测量下肢功能的方法有限。

目的

本研究的目的是使用倾斜运动器械测量两种下肢部分负重性能测量方法的评分者内信度,并评估这两种测量方法的同时效度和对变化的反应性。

方法

对37名成年下肢损伤患者进行了两种下肢部分负重性能测量(PWB20和PWB30)以及几种常见的下肢功能测量。在初始测试后,要求受试者在经过四至六周的康复干预后返回进行重新测试。使用组内相关系数(ICC)测试测量数据的信度;效度基于测量的双变量相关性。最小可检测变化(MDC)值和肢体对称指数(LSI)用于研究部分负重测量的反应性。

结果

PWB20和PWB30的ICC分别为0.95和0.98。PWB20与爬楼梯和步行速度的双变量相关性大于PWB30。部分负重测量与功能测量之间的相关性范围为r = 0.49至0.72。对于大多数患者,他们在初始测试和随访之间的得分变化超过了MDC;所有患者的LSI均有所改善。

结论

使用倾斜器械可产生可靠的部分负重数据。此外,部分负重测量的表现与常见的功能测量相关性相当好。

相似文献

2
The push-off test: development of a simple, reliable test of upper extremity weight-bearing capability.
J Hand Ther. 2014 Jul-Sep;27(3):185-90; quiz 191. doi: 10.1016/j.jht.2014.03.002. Epub 2014 Mar 12.
3
Validity and reliability of the unsupported upper-limb exercise test in individuals with rheumatoid arthritis.
Int J Rheum Dis. 2019 Nov;22(11):2025-2030. doi: 10.1111/1756-185X.13720. Epub 2019 Oct 9.
6
An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study.
Medicina (Kaunas). 2019 Aug 22;55(9):516. doi: 10.3390/medicina55090516.
7
Reliability and validity of a return to sports testing battery for the shoulder.
Phys Ther Sport. 2021 Mar;48:1-11. doi: 10.1016/j.ptsp.2020.12.003. Epub 2020 Dec 11.
8
Psychometric comparisons of 4 measures for assessing upper-extremity function in people with stroke.
Phys Ther. 2009 Aug;89(8):840-50. doi: 10.2522/ptj.20080285. Epub 2009 Jun 25.
9
Reliability of a shoulder arm return to sport test battery.
Phys Ther Sport. 2019 Sep;39:16-22. doi: 10.1016/j.ptsp.2019.06.001. Epub 2019 Jun 4.
10

引用本文的文献

1
Functional performance testing in athletes with functional ankle instability.
Asian J Sports Med. 2011 Dec;2(4):249-58. doi: 10.5812/asjsm.34741.

本文引用的文献

1
Intraclass correlations: uses in assessing rater reliability.
Psychol Bull. 1979 Mar;86(2):420-8. doi: 10.1037//0033-2909.86.2.420.
2
Test-retest reliability of isokinetic knee extension and flexion.
Arch Phys Med Rehabil. 2007 May;88(5):626-31. doi: 10.1016/j.apmr.2007.02.006.
4
Muscle strength assessment from functional performance tests: role of body size.
J Strength Cond Res. 2003 Nov;17(4):664-70. doi: 10.1519/1533-4287(2003)017<0664:msaffp>2.0.co;2.
5
Simple measurements in assessing muscle performance after an ACL reconstruction.
Int J Sports Med. 2002 Apr;23(3):196-201. doi: 10.1055/s-2002-23171.
6
Hop tests as predictors of dynamic knee stability.
J Orthop Sports Phys Ther. 2001 Oct;31(10):588-97. doi: 10.2519/jospt.2001.31.10.588.
8
Hip contact forces and gait patterns from routine activities.
J Biomech. 2001 Jul;34(7):859-71. doi: 10.1016/s0021-9290(01)00040-9.
9
Dynamic stability after ACL injury: who can hop?
Knee Surg Sports Traumatol Arthrosc. 2000;8(5):262-9. doi: 10.1007/s001670000130.
10
Ability of closed and open kinetic chain tests of muscular strength to assess functional performance.
Scand J Med Sci Sports. 2000 Jun;10(3):164-8. doi: 10.1034/j.1600-0838.2000.010003164.x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验