Suppr超能文献

吸入沙丁胺醇重复剂量的尿浓度。

Urine concentrations of repetitive doses of inhaled salbutamol.

机构信息

Bispebjerg Hospital, Respiratory Research Unit, København NV, Denmark.

出版信息

Int J Sports Med. 2011 Aug;32(8):574-9. doi: 10.1055/s-0031-1273755. Epub 2011 May 11.

Abstract

We examined blood and urine concentrations of repetitive doses of inhaled salbutamol in relation to the existing cut-off value used in routine doping control. We compared the concentrations in asthmatics with regular use of beta2-agonists prior to study and healthy controls with no previous use of beta2-agonists. We enrolled 10 asthmatics and 10 controls in an open-label study in which subjects inhaled repetitive doses of 400 microgram salbutamol every second hour (total 1600 microgram), which is the permitted daily dose by the World Anti-Doping Agency (WADA). Blood samples were collected at baseline, 30 min, 1, 2, 3, 4, and 6 h after the first inhalations. Urine samples were collected at baseline, 0-4 h, 4-8 h, and 8-12 h after the first inhalations. Median urine concentrations peaked in the period 4-8 h after the first inhalations in the asthmatics and between 8-12 h in controls and the median ranged from 268 to 611 ng×mL (-1). No samples exceeded the WADA threshold value of 1000 ng×mL (-1) when corrected for the urine specific gravity. When not corrected one sample exceeded the cut-off value with urine concentration of 1082 ng×mL (-1). In conclusion we found no differences in blood and urine concentrations between asthmatic and healthy subjects. We found high variability in urine concentrations between subjects in both groups. The variability between subjects was still present after the samples were corrected for urine specific gravity.

摘要

我们研究了吸入沙丁胺醇重复剂量与常规兴奋剂检测中现用截止值的关系。我们将使用β2-激动剂治疗的哮喘患者与未使用过β2-激动剂的健康对照者进行比较。我们进行了一项开放标签研究,纳入了 10 例哮喘患者和 10 例健康对照者,这些患者每两小时吸入 400 微克沙丁胺醇(共 1600 微克),这是世界反兴奋剂机构(WADA)允许的每日剂量。在第一次吸入前、第 30 分钟、第 1、2、3、4 和 6 小时采集血样。在第一次吸入后 0-4、4-8 和 8-12 小时采集尿样。哮喘患者尿中药物浓度的中位数在第一次吸入后 4-8 小时达到峰值,而对照组则在 8-12 小时达到峰值,中位数范围为 268-611 ng·mL(-1)。校正尿比重后,没有样本超过 WADA 的 1000ng·mL(-1)阈值。未校正时,一个样本的尿浓度为 1082ng·mL(-1),超过了截止值。结论:我们发现哮喘患者和健康对照者的血药和尿药浓度没有差异。我们发现两组受试者的尿药浓度存在很大的变异性。校正尿比重后,受试者之间的变异性仍然存在。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验