Division of Applied Acoustics, Chalmers University of Technology, S-41296 Gothenburg, Sweden.
J Acoust Soc Am. 2011 Jun;129(6):3827-36. doi: 10.1121/1.3573990.
This paper reports on listening tests performed to investigate the just audible tonality (JAT) of decaying pure tone bursts. Both exponential and Gaussian functions are used to shape the envelopes of the tone bursts and critical band center frequencies between 150 and 7000 Hz are studied. Loudness compensation is implemented to compensate for the reduced loudness of short tone bursts and attack functions are used for minimizing clicks. By using the method of limits, a sequence of tone bursts with increasing decay times and constant frequencies is presented to the listeners at 0.9 s intervals. The first burst in the sequence which is perceived as being tonal is indicated by the listeners. When that happens, the decay times of the tone bursts decrease and the listeners are asked to select the first tone burst with no audible tonality. The listeners are allowed to freely define tonality. No reference is given. For frequencies above 3.4 kHz, the results indicate that tonality is just audible for tone burst lengths of approximately 2.6-3.0 ms. For the lowest stimuli frequencies, the corresponding burst length is approximately 20-23 ms.
本文报告了用于研究衰减纯音猝发音的可听音调(JAT)的听力测试。实验采用指数函数和高斯函数来塑造猝发音的包络,研究了中心频率在 150Hz 到 7000Hz 之间的临界频带。采用响度补偿来补偿短猝发音的响度降低,并使用起始音来最小化咔嗒声。通过使用极限法,以 0.9 秒的间隔向听众呈现一系列具有恒定频率但衰减时间逐渐增加的猝发音。听众指出第一个被感知为有音调的猝发音。当这种情况发生时,猝发音的衰减时间会减小,听众被要求选择第一个没有可听音调的猝发音。听众可以自由定义音调。没有给出参考。对于高于 3.4kHz 的频率,结果表明,音调在大约 2.6-3.0ms 的猝发音长度下可被听出。对于最低的刺激频率,相应的猝发音长度大约为 20-23ms。