Department of Pharmacy, University of Peshawar, Peshawar-25120, Pakistan.
J Chromatogr B Analyt Technol Biomed Life Sci. 2011 Sep 1;879(25):2567-75. doi: 10.1016/j.jchromb.2011.07.013. Epub 2011 Jul 18.
A novel highly sensitive ion-pairing reversed-phase high performance liquid-chromatography/electrochemical detection method for simultaneous determination of l-ascorbic acid, aminothiols, and methionine in biological matrices was developed, optimized, and validated. Reduced forms of the analytes were extracted from the sample matrices with 10% meta-phosphoric acid solution((aqueous)). To determine the total vitamin C, the total aminothiols, and the total methionine, samples were treated with tris(2-carboxyethyl)phosphine solution in 0.05% trifluoroacetic acid solution((aqueous)) subsequent to deproteination to reduce the oxidized forms of these compounds. Various analytes were separated on a C(18) (250 × 4.6 mm, 5 μm) analytical column using methanol-0.05% trifluoroacetic acid solution((aqueous)) (05/95, v/v), containing 0.1mM 1-octane sulphonic acid as the ion-pairing agent) as the isocratic mobile phase pumped at a flow rate of 1.5 mL min(-1) at room temperature. The column eluents were monitored at a voltage of 0.85 V. These analytes were efficiently resolved in less than 20 min using n-acetyl cysteine as the internal standard. The present method was specific for the analysis of these analytes and demonstrated acceptable values for linearity (r(2)>0.999 in the range of 0.2-10,000 ng mL(-1) for all the analytes), recovery (>96%), precision (%RSD ≤ 2.0), and sensitivity (on column limit of detection: 250-400 fg and limit of quantification: 0.8-1.25 pg), indicating that the proposed method could be efficiently used for determination of these analytes in the context of clinical research.
建立、优化并验证了一种用于生物基质中 l-抗坏血酸、氨基硫醇和蛋氨酸同时测定的新型高灵敏离子对反相高效液相色谱/电化学检测方法。用 10%偏磷酸溶液(水相)从样品基质中提取分析物的还原形式。为了测定总维生素 C、总氨基硫醇和总蛋氨酸,样品先用三(2-羧乙基)膦溶液(0.05%三氟乙酸溶液(水相))处理,然后进行蛋白沉淀去除,以还原这些化合物的氧化形式。使用 C(18)(250×4.6mm,5μm)分析柱,以甲醇-0.05%三氟乙酸溶液(水相)(05/95,v/v)为等度流动相,其中含有 0.1mM 1-辛烷磺酸作为离子对试剂,流速为 1.5mL/min,在室温下进行洗脱,柱洗脱液在 0.85V 下进行监测。使用 N-乙酰半胱氨酸作为内标,这些分析物在不到 20 分钟内得到有效分离。该方法对这些分析物的分析具有特异性,并表现出良好的线性度(所有分析物在 0.2-10000ng/mL 范围内 r(2)>0.999)、回收率(>96%)、精密度(%RSD≤2.0)和灵敏度(柱上检测限:250-400fg,定量限:0.8-1.25pg),表明该方法可有效地用于临床研究中这些分析物的测定。