Micellar electrokinetic chromatography with acid labile surfactant.

机构信息

Department of Chemistry, Gunning/Lemieux Chemistry Centre, University of Alberta, Edmonton T6G 2G2, Alberta, Canada.

出版信息

J Chromatogr A. 2012 Feb 24;1226:55-60. doi: 10.1016/j.chroma.2011.09.065. Epub 2011 Sep 29.

Abstract

We present a study of a degradable surfactant, sodium 4-[(2-methyl-2-undecyl-1,3-dioxolan-4-yl)methoxy]-1-propane sulfonate that is also known as an acid-labile surfactant (ALS). The performance of ALS as a pseudostationary phase is assessed and compared with established pseudostationary phases such as sodium dodecyl sulphate (SDS), volatile surfactants and polymeric micelles. ALS achieves separation efficiency of 100,000-145,000 theoretical plates and relative standard deviation (RSD) of electrophoretic mobility (n=5) of less than 3%. Retention factors with ALS are strongly correlated with those with SDS. This is shown by the R2=0.79 for all eleven analytes and an R2=0.992 for specifically the non-hydrogen bonding (NHB) analytes. However, ALS displays different selectivity than SDS for hydrogen bond donor (HBD) and hydrogen bond acceptor (HBA) solutes (R2 of 0.74 and 0.88, respectively). ALS is degraded to less surface active compounds in acidic solution. These less surface-active compounds are more compatible with the electrospray ionization mass spectrometry (ESI-MS). ALS has a half-life of 48 min at pH 4. ALS has the potential to couple micellar electrokinetic chromatography (MEKC) with the ESI-MS. ALS can be used as a pseudostationary phase for a high efficiency separation and later acid hydrolyzed to enable an ESI-MS analysis.

摘要

我们提出了一种可降解表面活性剂的研究,即 4-[(2-甲基-2-十一烷基-1,3-二恶烷-4-基)甲氧基]-1-丙磺酸钠,也称为酸不稳定表面活性剂 (ALS)。评估了 ALS 作为伪固定相的性能,并与已建立的伪固定相如十二烷基硫酸钠 (SDS)、挥发性表面活性剂和聚合物胶束进行了比较。ALS 实现了 100,000-145,000 理论板的分离效率和电泳迁移率(n=5)的相对标准偏差(RSD)小于 3%。用 ALS 获得的保留因子与用 SDS 获得的保留因子强烈相关。这由所有 11 种分析物的 R2=0.79 和特别是非氢键供体 (NHB) 分析物的 R2=0.992 表明。然而,ALS 对氢键供体 (HBD) 和氢键受体 (HBA) 溶质表现出与 SDS 不同的选择性(分别为 R2=0.74 和 0.88)。ALS 在酸性溶液中降解为表面活性较低的化合物。这些表面活性较低的化合物与电喷雾电离质谱 (ESI-MS) 更兼容。ALS 在 pH 4 时的半衰期为 48 分钟。ALS 有可能将胶束电动色谱 (MEKC) 与 ESI-MS 结合使用。ALS 可用作高效分离的伪固定相,然后酸解以进行 ESI-MS 分析。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验