Benton Melissa J, Swan Pamela D, Schlairet Maura C, Sanderson Sonya
College of Nursing, Valdosta State University, Valdosta, Georgia 31698, USA.
Health Care Women Int. 2011 Dec;32(12):1068-78. doi: 10.1080/07399332.2011.603865.
Our purpose was to evaluate accuracy of multifrequency bioelectrical impedance analysis (MFBIA) using air displacement plethysmography (ADP) as the criterion measure. Body composition of 27 women was assessed by ADP followed immediately by MFBIA. There was a strong relationship (p = .01) between ADP and MFBIA in absolute lean mass (r = 0.80), absolute fat mass (r = 0.99), percent lean mass (r = 0.91), and percent fat mass (r = 0.91). Although MFBIA consistently overestimated lean mass and underestimated fat mass compared with ADP, agreement between measurements was within 2%-3% body fat. An accurate assessment tool, MFBIA can be useful in clinical settings.
我们的目的是使用空气置换体积描记法(ADP)作为标准测量方法来评估多频生物电阻抗分析(MFBIA)的准确性。对27名女性的身体成分进行了ADP评估,随后立即进行了MFBIA评估。在绝对瘦体重(r = 0.80)、绝对脂肪量(r = 0.99)、瘦体重百分比(r = 0.91)和脂肪量百分比(r = 0.91)方面,ADP与MFBIA之间存在很强的相关性(p = 0.01)。尽管与ADP相比,MFBIA始终高估了瘦体重并低估了脂肪量,但测量之间的一致性在体脂的2%-3%以内。作为一种准确的评估工具,MFBIA在临床环境中可能会很有用。