Suppr超能文献

金属-陶瓷或全陶瓷上部结构材料对单颗种植体支持修复体的应力分布的影响:三维有限元分析。

Effect of metal-ceramic or all-ceramic superstructure materials on stress distribution in a single implant-supported prosthesis: three-dimensional finite element analysis.

机构信息

Departement of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University, Brazil.

出版信息

Int J Oral Maxillofac Implants. 2011 Nov-Dec;26(6):1202-9.

Abstract

PURPOSE

This three-dimensional finite element analysis study evaluated the effect of different material combinations on stress distribution within metal-ceramic and all-ceramic single implant-supported prostheses.

MATERIALS AND METHODS

Three-dimensional finite element models reproducing a segment of the maxilla with a missing left first premolar were created. Five groups were established to represent different superstructure materials: GP, porcelain fused to gold alloy; GR, modified composite resin fused to gold alloy; TP, porcelain fused to titanium; TR, modified composite resin fused to titanium; and ZP, porcelain fused to zirconia. A 100-N vertical force was applied to the contact points of the crowns. All models were fixed in the superior region of bone tissue and in the mesial and distal faces of the maxilla section. Stress maps were generated by processing with finite element software.

RESULTS

Stress distribution and stress values of supporting bone were similar for the GP, GR, TP, and ZP models (1,574.3 MPa, 1,574.3 MPa, 1,574.3 MPa, and 1,574.2 MPa, respectively) and different for the TR model (1,838.3 MPa). The ZP model transferred less stress to the retention screw (785 MPa) than the other groups (939 MPa for GP, 961 MPa for GR, 1,010 MPa for TP, and 1,037 MPa for TR).

CONCLUSION

The use of different materials to fabricate a superstructure for a single implant-supported prosthesis did not affect the stress distribution in the supporting bone. The retention screw received less stress when a combination of porcelain and zirconia was used.

摘要

目的

本三维有限元分析研究评估了不同材料组合对金属陶瓷和全陶瓷单种植体支持修复体内部应力分布的影响。

材料与方法

创建了一个复制上颌骨缺失左侧第一前磨牙的三维有限元模型。建立了五个组来代表不同的上部结构材料:GP,金合金烤瓷;GR,金合金复合树脂烤瓷;TP,钛烤瓷;TR,钛复合树脂烤瓷;ZP,氧化锆烤瓷。将 100-N 的垂直力施加到冠的接触点上。所有模型均在上颌骨组织的上方区域和上颌骨节段的近中和远中面固定。通过有限元软件处理生成应力图。

结果

GP、GR、TP 和 ZP 模型的支撑骨的应力分布和应力值相似(分别为 1574.3 MPa、1574.3 MPa、1574.3 MPa 和 1574.2 MPa),而 TR 模型则不同(1838.3 MPa)。ZP 模型向固位螺钉传递的应力(785 MPa)小于其他组(GP 为 939 MPa,GR 为 961 MPa,TP 为 1010 MPa,TR 为 1037 MPa)。

结论

使用不同材料制造单种植体支持修复体的上部结构不会影响支撑骨的应力分布。当使用瓷和氧化锆组合时,固位螺钉承受的应力较小。