Suppr超能文献

新生儿肝内积液及其与特定脐静脉导管使用的关联:5例报告

Liver fluid collection in neonates and its association with the use of a specific umbilical vein catheter: Report of five cases.

作者信息

Mahajan Vikas, Rahman Asad, Tarawneh Amjad, Sant'anna Guilherme Mendes

机构信息

McMaster Children's Hospital, McMaster University, Hamilton, Ontario.

出版信息

Paediatr Child Health. 2011 Jan;16(1):13-5. doi: 10.1093/pch/16.1.13.

Abstract

In newborns, the presence of liver fluid collection is a rare event. The reported cases are isolated or described over long periods. Within four months, five neonates were diagnosed with liver fluid collection from safety occurrence reports. Clinical, laboratory and radiological data were extracted from medical records. The definite diagnosis was made by ultrasound. Four of the patients were preterm, male and had very low birth weights. The osmolality of the infused solution was within the acceptable range. Investigations revealed that the use of a new brand of umbilical vein catheter introduced in the neonatal intensive care unit, one month before the first case, was associated with this cluster. Low positioning of the umbilical vein catheter tip appeared to be a second contributory factor. Neonatal practitioners may benefit from the present report when facing the occurrence of similar lesions.

摘要

在新生儿中,肝脏积液的出现是一种罕见事件。报告的病例为散发病例或经过长时间描述。在四个月内,从安全事件报告中确诊了五例新生儿肝脏积液。从病历中提取了临床、实验室和放射学数据。通过超声做出明确诊断。其中四名患者为早产儿,男性,出生体重极低。输注溶液的渗透压在可接受范围内。调查显示,在第一例病例前一个月引入新生儿重症监护病房的一种新品牌脐静脉导管的使用与这一聚集性病例有关。脐静脉导管尖端位置过低似乎是第二个促成因素。新生儿从业者在面对类似病变的发生时可能会从本报告中受益。

相似文献

6
Ultrasound-guided umbilical catheter insertion in neonates.
J Perinatol. 2011 May;31(5):344-9. doi: 10.1038/jp.2010.128. Epub 2011 Feb 10.
8
[Catheter tip position and risk of mechanical complications in a neonatal unit].
An Pediatr (Barc). 2016 Aug;85(2):77-85. doi: 10.1016/j.anpedi.2015.10.011. Epub 2015 Dec 2.

引用本文的文献

1
Utility of point-of-care ultrasound of the liver in the neonatal intensive care unit: experience from a case series.
Front Pediatr. 2025 Aug 29;13:1632908. doi: 10.3389/fped.2025.1632908. eCollection 2025.
2
Umbilical venous catheterization gone wrong: Hepatic complications.
Indian J Radiol Imaging. 2016 Jan-Mar;26(1):40-3. doi: 10.4103/0971-3026.178287.

本文引用的文献

1
Liver abscess in neonates.
Pediatr Surg Int. 2009 Feb;25(2):153-6. doi: 10.1007/s00383-008-2307-5. Epub 2008 Dec 17.
2
Hepatic laceration because of malpositioning of the umbilical vein catheter: case report and literature review.
J Pediatr Surg. 2008 May;43(5):E39-41. doi: 10.1016/j.jpedsurg.2008.01.018.
6
Mal-positioned umbilical venous catheter causing liver abscess in a preterm infant.
Biol Neonate. 2005;88(1):54-6. doi: 10.1159/000084718. Epub 2005 Mar 30.
7
Intravascular catheter complications in the neonatal intensive care unit.
Clin Perinatol. 2005 Mar;32(1):141-56, vii. doi: 10.1016/j.clp.2004.11.005.
8
Neonatal ascites and hyponatraemia following umbilical venous catheterization.
J Paediatr Child Health. 2002 Dec;38(6):612-4. doi: 10.1046/j.1440-1754.2002.00051.x.
9
Neonatal total parenteral nutrition ascites from liver erosion by umbilical vein catheters.
Pediatr Radiol. 1998 Dec;28(12):923-7. doi: 10.1007/s002470050500.
10
Roentgenologic features of umbilical vascular catheterization in the newborn.
Am J Roentgenol Radium Ther Nucl Med. 1971 May;112(1):68-76. doi: 10.2214/ajr.112.1.68.