Suppr超能文献

组合区域折射和衍射非球面多焦点人工晶状体。

Combining zonal refractive and diffractive aspheric multifocal intraocular lenses.

机构信息

Centro Oftalmológico Marqués de Sotelo, Valencia, Spain.

出版信息

J Refract Surg. 2012 Mar;28(3):174-81. doi: 10.3928/1081597X-20120215-02.

Abstract

PURPOSE

To assess visual performance with the combination of a zonal refractive aspheric multifocal intraocular lens (MIOL) (Lentis Mplus, Oculentis GmbH) and a diffractive aspheric MIOL (Acri.Lisa 366, Acri.Tech GmbH).

METHODS

This prospective interventional cohort study comprised 80 eyes from 40 cataract patients (mean age: 65.5±7.3 years) who underwent implantation of the Lentis Mplus MIOL in one eye and Acri.Lisa 366 MIOL in the fellow eye. The main outcome measures were refraction; monocular and binocular uncorrected and corrected distance, intermediate, and near visual acuities; monocular and binocular defocus curves; binocular photopic contrast sensitivity function compared to a monofocal intraocular lens (IOL) control group (40 age-matched pseudophakic patients implanted with the AR-40e [Abbott Medical Optics]); and quality of vision questionnaire.

RESULTS

Binocular uncorrected visual acuities were 0.12 logMAR (0.76 decimal) or better at all distances measured between 6 m and 33 cm. The Lentis Mplus provided statistically significant better vision than the Acri.Lisa at distances between 2 m and 40 cm, and the Acri.Lisa provided statistically significant better vision than the Lentis Mplus at 33 cm. Binocular defocus curve showed little drop-off at intermediate distances. Photopic contrast sensitivity function for distance and near were similar to the monofocal IOL control group except for higher frequencies. Moderate glare (15%), night vision problems (12.5%), and halos (10%) were reported. Complete independence of spectacles was achieved by 92.5% of patients.

CONCLUSIONS

The combination of zonal refractive aspheric and diffractive aspheric MIOLs resulted in excellent uncorrected binocular distance, intermediate, and near vision, with low incidence of significant photic phenomena and high patient satisfaction.

摘要

目的

评估区域折射非球面多焦点人工晶状体(MIOL)(Lentis Mplus,Oculentis GmbH)与衍射非球面 MIOL(Acri.Lisa 366,Acri.Tech GmbH)联合应用的视觉效果。

方法

本前瞻性干预性队列研究纳入 40 例白内障患者(平均年龄:65.5±7.3 岁)的 80 只眼,这些患者的一眼植入 Lentis Mplus MIOL,另一眼植入 Acri.Lisa 366 MIOL。主要观察指标包括:屈光度;单眼和双眼未矫正和矫正的远、中、近视力;单眼和双眼离焦曲线;与单焦点人工晶状体(IOL)对照组(40 例年龄匹配的白内障患者植入 AR-40e [Abbott Medical Optics])相比的双眼明视对比度敏感函数;以及视觉质量调查问卷。

结果

在 6m 至 33cm 的所有距离测量中,双眼未矫正视力均为 0.12 logMAR(0.76 十进制)或更好。Lentis Mplus 在 2m 至 40cm 的距离上提供了统计学上显著优于 Acri.Lisa 的视力,而 Acri.Lisa 在 33cm 处提供了统计学上显著优于 Lentis Mplus 的视力。中间距离的双眼离焦曲线几乎没有下降。距离和近视力的明视对比敏感度函数与单焦点 IOL 对照组相似,除了高频部分。有 12.5%的患者报告存在中度眩光(15%)、夜视问题(12.5%)和光晕(10%)。92.5%的患者实现了完全不依赖眼镜。

结论

区域折射非球面和衍射非球面 MIOL 的联合应用可获得出色的双眼远、中、近视力,且光像差发生率低,患者满意度高。