Lawrie S R, Faircloth D C, Philippe K
ISIS Pulsed Neutron and Muon Source, Rutherford Appleton Laboratory, Oxfordshire, OX11 0QX, United Kingdom.
Rev Sci Instrum. 2012 Feb;83(2):02A704. doi: 10.1063/1.3662959.
The front end test stand is being constructed at the Rutherford Appleton Laboratory, with the aim of producing a 60 mA, 2 ms, 50 Hz, perfectly chopped H(-) ion beam. To meet the beam requirements, a more detailed understanding of the ion source plasma is required. To this end, an initial study is made of the optical spectrum of the plasma using a digital spectrometer. The atomic and molecular emission lines of hydrogen and caesium are clearly distinguished and a quantitative comparison is made when the ion source is run in different conditions. The electron temperature is 0.6 eV and measured line widths vary by up to 75%.