Meadowview Orthopaedic Care Center, Maysville, Kentucky, USA.
J Arthroplasty. 2012 Jun;27(6):1251-3. doi: 10.1016/j.arth.2012.01.025. Epub 2012 Mar 14.
Core decompression and placement of the Trabecular Metal Osteonecrosis Intervention Implant have shown to be initially successful in treating early osteonecrosis. When treatment fails, however, patients often undergo primary total hip arthroplasty (THA) requiring removal of a previously inserted trabecular metal implant. We describe a technical tip for removal of a well-ingrown trabecular metal screw. A metal-cutting trephine placed over the screw allows for removal in an efficient manner while minimizing additional dissection and bone loss during conversion to THA.
核心减压和小梁金属骨坏死介入植入物的放置已被证明在治疗早期骨坏死方面最初是成功的。然而,当治疗失败时,患者通常需要进行初次全髋关节置换术 (THA),需要取出先前插入的小梁金属植入物。我们描述了一种取出完全长入骨内的小梁金属螺钉的技术窍门。将金属切割环钻置于螺钉上方,可在转换为 THA 时以最小的额外解剖和骨丢失的方式高效地取出螺钉。