Suppr超能文献

[采用动态反应池电感耦合等离子体质谱法直接测定血清中的21种元素]

[Direct determination of 21 elements in serum by dynamic reaction cell inductively coupled plasma mass spectrometry].

作者信息

Li Hui-ling, Ma Jing, Zhang Yang

机构信息

Department of Occupationgl Disease and Toxication, Chaoyang Hospital Affiliated to the Capital University of Medical Science, Beijing 100020, China.

出版信息

Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2011 Nov;29(11):858-60.

Abstract

OBJECTIVE

To establish a method to directly determine 21 elements in serum by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS).

METHODS

The serum samples were diluted with 1% nitric acid by 3 times. The inductively coupled plasma mass spectrometry (ICP-MS) was used simultaneously to detect the serum concentrations of 21 elements (Be, Al, Mn, V, Cr, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Ag, Cd, Sb, Ba, T1, Ph, Th, U).

RESULTS

The detection limits of all elements were between 0.001-0.0711 g/1. Standard linear correlation coefficients (r) were 50.999. Standard deviations were less than 5%,the recovery rates were 90%-114%. Standard reference materials were used for quality control standards and the analysis results conformed with the certified values.

CONCLUSION

The present method is a simple, rapid,sensitive and accurate method for detecting the serum samples.

摘要

目的

建立一种通过动态反应池电感耦合等离子体质谱法(DRC-ICP-MS)直接测定血清中21种元素的方法。

方法

血清样本用1%硝酸稀释3倍。采用电感耦合等离子体质谱法(ICP-MS)同时检测血清中21种元素(铍、铝、锰、钒、铬、铁、钴、镍、铜、锌、砷、硒、钼、银、镉、锑、钡、铊、铅、钍、铀)的浓度。

结果

所有元素的检测限在0.001 - 0.0711μg/L之间。标准线性相关系数(r)均大于0.999。标准偏差小于5%,回收率为90% - 114%。采用标准参考物质作为质量控制标准,分析结果与认定值相符。

结论

本方法是一种检测血清样本的简单、快速、灵敏且准确的方法。

相似文献

2
[Measurement of 16 elements in blood by inductively coupled plasma mass spectrometry].
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2012 Jul;30(7):540-2.
3
Determination of trace elements by inductively coupled plasma mass spectrometry of biomass and fuel oil reference materials using milligram sample sizes.
Rapid Commun Mass Spectrom. 2000;14(5):335-43. doi: 10.1002/(SICI)1097-0231(20000315)14:5<335::AID-RCM854>3.0.CO;2-0.
6
Alkali dilution of blood samples for high throughput ICP-MS analysis-comparison with acid digestion.
Clin Biochem. 2015 Feb;48(3):140-7. doi: 10.1016/j.clinbiochem.2014.12.003. Epub 2014 Dec 9.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验