Mashhadi S A, Chandrasekharan L, Pickford M A
St. Thomas Hospital, London, UK.
J Hand Surg Eur Vol. 2012 Jul;37(6):501-5. doi: 10.1177/1753193412443044. Epub 2012 Apr 16.
A retrospective study was undertaken to review the outcomes of a consecutive series of patients treated using pyrocarbon surface replacement arthroplasty by the same surgeon. We analyzed the results of this procedure in 24 proximal interphalangeal (PIP) joints in 19 hands of 16 patients. The minimum follow-up was 3 years. The study showed that pyrocarbon PIP joint replacements provided excellent pain relief and high patient satisfaction. More than two-thirds of patients subjectively rated postoperative range of motion and functional outcomes as better than preoperatively. Objective assessment showed a modest improvement in the active range of motion, which did not achieve statistical significance, although we did observe a statistically significant increase in passive range of motion. The results are encouraging for those surgeons who seek an alternative to silicone implant PIP joint arthroplasty in high-demand patients.
我们进行了一项回顾性研究,以评估同一位外科医生采用热解碳表面置换关节成形术治疗的一系列连续患者的治疗效果。我们分析了16例患者19只手中24个近端指间(PIP)关节的手术结果。最短随访时间为3年。研究表明,热解碳PIP关节置换术能有效缓解疼痛,患者满意度高。超过三分之二的患者主观认为术后活动范围和功能结果优于术前。客观评估显示主动活动范围有适度改善,但未达到统计学意义,不过我们确实观察到被动活动范围有统计学意义的增加。对于那些在高需求患者中寻求替代硅胶植入PIP关节置换术的外科医生来说,这些结果令人鼓舞。