Registre Bourguignon des Cancers Digestifs, INSERM U866, Université de Bourgogne, CHU Dijon, 7 Boulevard Jeanne d'Arc, 21079 Dijon Cedex, France.
Eur J Cancer. 2012 Nov;48(16):2969-76. doi: 10.1016/j.ejca.2012.04.007. Epub 2012 May 7.
The aim of this study was to compare the performance of the guaiac-based faecal occult blood test (G-FOBT), with that of three immunochemical faecal occult blood tests (I-FOBT) which allow automatic interpretation.
Under the French organised screening programme, 85,149 average-risk individuals aged 50-74 participating in the third screening round, performed both the G-FOBT (Hemoccult-II test) and one of the I-FOBTs: FOB-Gold, Magstream and OC-Sensor.
Given the chosen threshold, the positivity ratio between the different I-FOBTs and the G-FOBT was 2.4 for FOB-Gold, 2.0 for Magstream and 2.2 for OC-Sensor (P=0.17). The three I-FOBTs were superior to the G-FOBT for colorectal cancer (CRC) detection. The ratios for detection rates were 1.6 (FOB-Gold), 1.7 (Magstream) and 2.1 (OC-Sensor) (P=0.74). For non-invasive CRC they were, respectively, 2.5, 3.0 and 4.0 (P=0.83) and for advanced adenomas 3.6, 3.1 and 4.0 (P=0.39).
This study provides further evidence that I-FOBT is superior to G-FOBT. None of the three I-FOBTs studied appeared to be significantly better than the others.
本研究旨在比较基于愈创木脂的粪便潜血试验(G-FOBT)与三种可自动判读的免疫粪便潜血试验(I-FOBT)的性能。
在法国组织的筛查计划下,85149 名年龄在 50-74 岁的平均风险个体参加了第三轮筛查,同时进行 G-FOBT(Hemoccult-II 试验)和三种 I-FOBTs 之一的检测:FOB-Gold、Magstream 和 OC-Sensor。
在选择的阈值下,不同的 I-FOBTs 与 G-FOBT 的阳性比值分别为 FOB-Gold 为 2.4,Magstream 为 2.0,OC-Sensor 为 2.2(P=0.17)。三种 I-FOBTs 在结直肠癌(CRC)检测方面均优于 G-FOBT。检测率的比值分别为 1.6(FOB-Gold)、1.7(Magstream)和 2.1(OC-Sensor)(P=0.74)。对于非侵袭性 CRC,其比值分别为 2.5、3.0 和 4.0(P=0.83),对于高级腺瘤分别为 3.6、3.1 和 4.0(P=0.39)。
本研究进一步证明 I-FOBT 优于 G-FOBT。三种研究中的 I-FOBT 均未表现出明显优于其他的情况。